Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Emission.Examples.MozartRFBoiler.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001228/0.001228, allocations: 114.3 kB / 18.94 MB, free: 2.793 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001418/0.001418, allocations: 219.9 kB / 22.26 MB, free: 5.211 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.471/1.471, allocations: 230.6 MB / 256 MB, free: 7.992 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/Building/BuildingEnvelope/HeatTransfer/package.mo:2:1-40:17:writable] Warning: Soil_case_nappe was referenced in the package.order file, but was not found in package.mo, Soil_case_nappe/package.mo or Soil_case_nappe.mo. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/package.mo): time 0.9483/0.9483, allocations: 145 MB / 457.4 MB, free: 15.5 MB / 366.1 MB " [Timeout remaining time 179] Using package BuildSysPro with version 3.6.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(BuildSysPro.Systems.HVAC.Emission.Examples.MozartRFBoiler,fileNamePrefix="BuildSysPro_BuildSysPro_Systems_HVAC_Emission_Examples_MozartRFBoiler",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildSysPro.Systems.HVAC.Emission.Examples.MozartRFBoiler,fileNamePrefix="BuildSysPro_BuildSysPro_Systems_HVAC_Emission_Examples_MozartRFBoiler",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: BuildSysPro requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002296/0.002296, allocations: 66.12 kB / 0.6331 GB, free: 7.328 MB / 462.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.191/0.1933, allocations: 87.89 MB / 0.719 GB, free: 15.44 MB / 0.545 GB Notification: Performance of NFInst.instantiate(BuildSysPro.Systems.HVAC.Emission.Examples.MozartRFBoiler): time 0.3899/0.5831, allocations: 46.67 MB / 0.7645 GB, free: 3.77 MB / 0.5606 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/BaseClasses/Media/OLD_THERMHYGAERO/AirFunctions/Psat.mo:3:3-3:24:writable] Error: Invalid public variable AH, function variables that are not input/output must be protected. Notification: Performance of FrontEnd: time 0.0009902/0.5841, allocations: 0.5216 MB / 0.765 GB, free: 3.75 MB / 0.5606 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.020066431956366] Failed to read output from testmodel.py, exit status != 0: 0.5909936781972647 0.605159132 -1.0 Calling exit ...