/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_LoadAggregation_Validation_TemperatureResponseMatrix_fmu --startTime=0 --stopTime=3.1536e+07 --stepSize=12614.4 --timeout=50 --tolerance=1e-06 BuildSysPro_BuildSysPro_IBPSA_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_LoadAggregation_Validation_TemperatureResponseMatrix.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemperatureResponseMatrix" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemperatureResponseMatrix" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemperatureResponseMatrix/model-9g6ej3b4" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemperatureResponseMatrix" info: *** FMU Simulation Info *** - model: model (model exchange) - path: BuildSysPro_BuildSysPro_IBPSA_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_LoadAggregation_Validation_TemperatureResponseMatrix.fmu - startTime: 0.000000 - stopTime: 31536000.000000 - tolerance: 0.000001 - stepSize: 12614.400000 info: model doesn't contain any continuous state LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/TemperatureResponseMatrix_validationTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/TemperatureResponseMatrix_validationTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/TemperatureResponseMatrix_validationTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/TemperatureResponseMatrix_validationTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/TemperatureResponseMatrix_validationTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/TemperatureResponseMatrix_validationTStep.mat" LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemperatureResponseMatrix/520.fmutmp/sources/gc/memory_pool.c:100: pool_expand: Assertion `0 && "Attempt to allocate an unusually large memory. The memory management does not seem to be working as intended. Please create an issue on https://github.com/OpenModelica/OpenModelica/issues."` failed. error: [fmi2logger] [fmi2Error] BuildSysPro_BuildSysPro_IBPSA_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_LoadAggregation_Validation_TemperatureResponseMatrix/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.BuildSysPro_BuildSysPro_IBPSA_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_LoadAggregation_Validation_TemperatureResponseMatrix" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors