/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case600FF_fmu --startTime=0 --stopTime=3.15396e+07 --stepSize=12615.8 --timeout=50 --tolerance=1e-06 AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case600FF.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case600FF" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case600FF" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case600FF/model-vqlu9rhf" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case600FF" info: *** FMU Simulation Info *** - model: model (model exchange) - path: AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case600FF.fmu - startTime: 0.000000 - stopTime: 31539600.000000 - tolerance: 0.000001 - stepSize: 12615.800000 LOG_STDOUT | info | ... loading "Table" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case600FF/model-vqlu9rhf/temp/0001_AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case600FF/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Resources/weatherdata/Weatherdata_ASHARE140.txt" LOG_STDOUT | info | ... loading "Table" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case600FF/model-vqlu9rhf/temp/0001_AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case600FF/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Resources/weatherdata/Weatherdata_ASHARE140.txt" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Utilities/HeatTransfer/SolarRadInRoom.mo:162:3-162:212:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(Room.solarRadInRoom.solar_frac_cei[1] + Room.solarRadInRoom.solar_frac_flo[1] + Room.solarRadInRoom.solar_frac_wall[1] + Room.solarRadInRoom.solar_frac_wall[2] + Room.solarRadInRoom.solar_frac_wall[3] + Room.solarRadInRoom.solar_frac_wall[4] + Room.solarRadInRoom.solar_frac_win_lost[1] + Room.solarRadInRoom.solar_frac_win_abs[1] - 1.0) < 2.220446049250313e-16)) --> "Sum of solar fractions is not equal to 1" error: [fmi2logger] [fmi2Error] AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case600FF/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.AixLib_AixLib_ThermalZones_HighOrder_Validation_ASHRAE140_Case600FF" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors