Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr AES_AES.ProcessComponents.Thermal.DistrictHeating.TwinPipeSubstation.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001944/0.001944, allocations: 110.4 kB / 18.94 MB, free: 2.949 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0025/0.0025, allocations: 218.2 kB / 22.25 MB, free: 5.117 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.531/1.531, allocations: 230.6 MB / 256 MB, free: 7.957 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/package.mo): time 0.1145/0.1145, allocations: 24.13 MB / 336.6 MB, free: 11.4 MB / 270.1 MB " [Timeout remaining time 180] Using package AES with version (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(AES.ProcessComponents.Thermal.DistrictHeating.TwinPipeSubstation,fileNamePrefix="AES_AES_ProcessComponents_Thermal_DistrictHeating_TwinPipeSubstation",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(AES.ProcessComponents.Thermal.DistrictHeating.TwinPipeSubstation,fileNamePrefix="AES_AES_ProcessComponents_Thermal_DistrictHeating_TwinPipeSubstation",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: AES requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002207/0.002207, allocations: 59.91 kB / 473.3 MB, free: 6.348 MB / 334.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3505/0.3527, allocations: 59.61 MB / 0.5204 GB, free: 10.1 MB / 382.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/ProcessComponents/Thermal/Interfaces/flowTwoTwinPorts_pwh.mo:4:3-4:45:writable] Error: The model can't be instantiated due to top-level outer element 'system', it may only be used as part of a simulation model. Notification: Performance of FrontEnd: time 0.003498/0.3562, allocations: 2.836 MB / 0.5232 GB, free: 8.062 MB / 382.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.9314868999645114] Failed to read output from testmodel.py, exit status != 0: 0.36341487313620746 0.37766029599999995 -1.0 Calling exit ...