Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001855/0.001855, allocations: 109.2 kB / 18.94 MB, free: 2.949 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002561/0.002561, allocations: 219.7 kB / 22.26 MB, free: 5.125 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.407/1.407, allocations: 230.6 MB / 256 MB, free: 7.984 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.7798/0.7798, allocations: 100.3 MB / 412.7 MB, free: 3.664 MB / 318.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_fillingClosedTank",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_fillingClosedTank",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002352/0.002352, allocations: 90.16 kB / 0.5633 GB, free: 35.95 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1437/0.146, allocations: 74.46 MB / 0.636 GB, free: 7.676 MB / 478.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank): time 0.6119/0.758, allocations: 264.8 MB / 0.8946 GB, free: 9.613 MB / 0.6387 GB Notification: Performance of NFInst.instExpressions: time 0.01008/0.7681, allocations: 6.279 MB / 0.9007 GB, free: 3.316 MB / 0.6387 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001423/0.7695, allocations: 39.69 kB / 0.9007 GB, free: 3.277 MB / 0.6387 GB Notification: Performance of NFTyping.typeComponents: time 0.002225/0.7717, allocations: 0.8666 MB / 0.9016 GB, free: 2.406 MB / 0.6387 GB Notification: Performance of NFTyping.typeBindings: time 0.008043/0.7798, allocations: 3.193 MB / 0.9047 GB, free: 15.2 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.003122/0.7829, allocations: 1.129 MB / 0.9058 GB, free: 14.07 MB / 0.6544 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.1202244970008906] Failed to read output from testmodel.py, exit status != 0: 0.7896457640017616 0.8053453150000001 -1.0 Calling exit ...