Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr IDEAS_IDEAS.Buildings.Validation.Tests.Case650.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001297/0.001297, allocations: 110.4 kB / 18.94 MB, free: 2.949 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001455/0.001455, allocations: 215.8 kB / 22.26 MB, free: 5.125 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.398/1.398, allocations: 230.6 MB / 256 MB, free: 7.961 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo): time 0.8059/0.8059, allocations: 134 MB / 446.4 MB, free: 10.23 MB / 350.1 MB " [Timeout remaining time 179] Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(IDEAS.Buildings.Validation.Tests.Case650,fileNamePrefix="IDEAS_IDEAS_Buildings_Validation_Tests_Case650",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(IDEAS.Buildings.Validation.Tests.Case650,fileNamePrefix="IDEAS_IDEAS_Buildings_Validation_Tests_Case650",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: IDEAS requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001924/0.001924, allocations: 76.41 kB / 0.6186 GB, free: 7.191 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1539/0.1559, allocations: 85.9 MB / 0.7024 GB, free: 1.371 MB / 0.5137 GB Notification: Performance of NFInst.instantiate(IDEAS.Buildings.Validation.Tests.Case650): time 1.304/1.46, allocations: 481.4 MB / 1.173 GB, free: 1.219 MB / 0.8262 GB Notification: Performance of NFInst.instExpressions: time 0.08467/1.545, allocations: 63.22 MB / 1.234 GB, free: 12.04 MB / 0.8419 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01603/1.561, allocations: 0.5037 MB / 1.235 GB, free: 12.04 MB / 0.8419 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/InterzonalAirFlow/BaseClasses/PartialInterzonalAirFlowBoundary.mo:21:3-22:72:writable] Warning: Connector weaBus is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialZone.mo:195:3-207:27:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Zone.mo:6:3-18:28:writable] Warning: Connector propsBus is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/BoundaryWall.mo:64:3-66:71:writable] Warning: Connector weaBus is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01905/1.58, allocations: 7.777 MB / 1.242 GB, free: 9.176 MB / 0.8419 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Templates/Interfaces/BaseClasses/Structure.mo:50:63-50:98:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Templates/Interfaces/BaseClasses/Structure.mo:50:3-52:73:writable] Error: Non-array modification '\"ThermodynamicTemperature\"' for array component 'quantity', possibly due to missing 'each'. Notification: Performance of FrontEnd: time 0.0001875/1.58, allocations: 47.91 kB / 1.242 GB, free: 9.156 MB / 0.8419 GB " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 4.733075288000691] Failed to read output from testmodel.py, exit status != 0: 1.586358641005063 1.601466032 -1.0 Calling exit ...