python3 -m fmpy simulate --output-file BuildingSystems_BuildingSystems.Buildings.Constructions.Examples.Door_res.csv --start-time 0 --stop-time 86400 --timeout 50 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 34.56 BuildingSystems_BuildingSystems_Buildings_Constructions_Examples_Door.fmu LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmpeo4yhss9/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/weather/USA_SanFrancisco.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Airflow/Multizone/MediumColumn.mo:10:3-10:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zone.airpath[1].h >= 0.0)) --> "Variable violating min constraint: 0.0 <= zone.airpath[1].h, has value: -0.9" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/WeatherData/BaseClasses/WeatherDataFileGeneral.mo:16:3-17:24:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ambience.weatherDataReader.weatherData.phiAir >= 0.0 and ambience.weatherDataReader.weatherData.phiAir <= 1.01)) --> "Variable violating min/max constraint: 0.0 <= ambience.weatherDataReader.weatherData.phiAir <= 1.01, has value: 1.0225" Traceback (most recent call last): File "/usr/lib/python3.10/runpy.py", line 196, in _run_module_as_main return _run_code(code, main_globals, None, File "/usr/lib/python3.10/runpy.py", line 86, in _run_code exec(code, run_globals) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/__main__.py", line 4, in main() File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/command_line.py", line 169, in main result = simulate_fmu(args.fmu_filename, File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/simulation.py", line 759, in simulate_fmu result = simulateME(model_description, fmu, start_time, stop_time, solver, step_size, relative_tolerance, start_values, apply_default_start_values, input, output, output_interval, record_events, timeout, step_finished, validate, set_stop_time) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/simulation.py", line 1059, in simulateME state_event, roots_found, time = solver.step(time, t_next) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/sundials/__init__.py", line 178, in step raise RuntimeError("CVode error (code %s) in module %s, function %s: %s" % self.error_info) RuntimeError: CVode error (code -1) in module CVODE, function CVode: At t = 7508.75, mxstep steps taken before reaching tout.