Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_selfDraining.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001916/0.001916, allocations: 113.5 kB / 19.73 MB, free: 2.242 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001999/0.001999, allocations: 220.9 kB / 23.05 MB, free: 5.074 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.464/1.464, allocations: 230.6 MB / 256.8 MB, free: 8.016 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.7912/0.7912, allocations: 100.3 MB / 413.5 MB, free: 3.664 MB / 318.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_selfDraining,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_selfDraining",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_selfDraining,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_selfDraining",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002446/0.002446, allocations: 83.38 kB / 0.564 GB, free: 35.82 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1372/0.1396, allocations: 74.46 MB / 0.6367 GB, free: 7.668 MB / 478.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Undirected.Boundaries.Tests.Tank_selfDraining): time 0.72/0.8596, allocations: 285.5 MB / 0.9156 GB, free: 4.785 MB / 0.6544 GB Notification: Performance of NFInst.instExpressions: time 0.01118/0.8708, allocations: 6.777 MB / 0.9222 GB, free: 13.98 MB / 0.67 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001808/0.8726, allocations: 55.5 kB / 0.9222 GB, free: 13.93 MB / 0.67 GB Notification: Performance of NFTyping.typeComponents: time 0.002726/0.8754, allocations: 0.8975 MB / 0.9231 GB, free: 13.03 MB / 0.67 GB Notification: Performance of NFTyping.typeBindings: time 0.01126/0.8866, allocations: 3.808 MB / 0.9268 GB, free: 9.203 MB / 0.67 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.002833/0.8895, allocations: 0.775 MB / 0.9276 GB, free: 8.43 MB / 0.67 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.276944523095153] Failed to read output from testmodel.py, exit status != 0: 0.8976024569710717 0.912703903 -1.0 Calling exit ...