/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Compressor_res.mat --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor_fmu --startTime=0 --stopTime=30 --stepSize=0.03 --timeout=1200 --tolerance=1e-06 ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Compressor" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Compressor" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Compressor/model-z1j2nia1" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Compressor" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor.fmu - startTime: 0.000000 - stopTime: 30.000000 - tolerance: 0.000001 - stepSize: 0.030000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:1022:7-1022:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sink.inlet.state.T >= 1.0 and sink.inlet.state.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= sink.inlet.state.T <= 1e4, has value: -694.44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:1022:7-1022:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((junctionN.inlets[2].state.T >= 1.0 and junctionN.inlets[2].state.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= junctionN.inlets[2].state.T <= 1e4, has value: -704.286" info: Result file: ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Compressor_res.mat (bufferSize=1) info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor.sink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor.sink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Compressor.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: 2 warnings info: 0 errors