Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankFillingClosedTank.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001942/0.001942, allocations: 113.5 kB / 19.73 MB, free: 2.242 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001996/0.001996, allocations: 217.5 kB / 23.04 MB, free: 5.078 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.445/1.445, allocations: 230.6 MB / 256.8 MB, free: 8.016 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.7792/0.7792, allocations: 100.3 MB / 413.5 MB, free: 3.703 MB / 318.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Boundaries.Tests.TankFillingClosedTank,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Boundaries_Tests_TankFillingClosedTank",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Boundaries.Tests.TankFillingClosedTank,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Boundaries_Tests_TankFillingClosedTank",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002431/0.002431, allocations: 82.58 kB / 0.564 GB, free: 35.8 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1316/0.134, allocations: 74.47 MB / 0.6367 GB, free: 7.668 MB / 478.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Boundaries.Tests.TankFillingClosedTank): time 0.6358/0.7699, allocations: 274.2 MB / 0.9045 GB, free: 144 kB / 0.6387 GB Notification: Performance of NFInst.instExpressions: time 0.01275/0.7826, allocations: 7.231 MB / 0.9115 GB, free: 8.887 MB / 0.6544 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001509/0.7841, allocations: 31.69 kB / 0.9116 GB, free: 8.855 MB / 0.6544 GB Notification: Performance of NFTyping.typeComponents: time 0.002663/0.7868, allocations: 0.8238 MB / 0.9124 GB, free: 8.027 MB / 0.6544 GB Notification: Performance of NFTyping.typeBindings: time 0.01111/0.7979, allocations: 3.932 MB / 0.9162 GB, free: 4.082 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.002971/0.8009, allocations: 0.989 MB / 0.9172 GB, free: 3.098 MB / 0.6544 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.106711392989382] Failed to read output from testmodel.py, exit status != 0: 0.8074082370148972 0.833637552 -1.0 Calling exit ...