/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmu
warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input
warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input
info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2"
info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2"
info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2/model-xwlmhe29"
info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2"
info: *** FMU Simulation Info ***
- model: model (co-simulation)
- path: Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmu
- startTime: 0.000000
- stopTime: 3600.000000
- tolerance: 0.000001
- stepSize: 1.440000
LOG_SOLVER | info | CVODE linear multistep method CV_BDF
LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON
LOG_SOLVER | info | CVODE use equidistant time grid YES
LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06
LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense.
LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method.
LOG_SOLVER | info | CVODE uses internal root finding method NO
LOG_SOLVER | info | CVODE maximum absolut step size 0
LOG_SOLVER | info | CVODE initial step size is set automatically
LOG_SOLVER | info | CVODE maximum integration order 5
LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10
LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Using pre-compiled FMU /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2/model-xwlmhe29/temp/0001_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/src/ThermalZones/EnergyPlus/FMUs/Zones3.fmu
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.core.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.north.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.south.#10;"
info: Result file: model_res.mat (bufferSize=10)
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.epwName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.fmuName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.idfName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.zoneName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.epwName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.fmuName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.idfName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.zoneName will not be stored in the result file, because the signal type is not supported
LOG_STDOUT | info | 60.480 FMUZoneAdapterZones2.building: Error from EnergyPlus: Current time 6.0480000000000004E+01 is after next time event 6.0000000000000000E+01. Consider to change option 2.2204460492503131E-14.
LOG_ASSERT | debug | 60.480 FMUZoneAdapterZones2.fmuZonSou: Failed to enter event mode in SpawnUtil.c, returned status is Error.
error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2/logFmi2Call: internalEventUpdate: terminated by an assertion.
info: 2 warnings
info: 1 errors