Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_12_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatPumpGroupAirToWater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001716/0.001716, allocations: 113 kB / 19.73 MB, free: 2.227 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002074/0.002074, allocations: 215 kB / 23.04 MB, free: 5.066 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.506/1.506, allocations: 230.6 MB / 256.8 MB, free: 8.035 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo): time 3.266/3.266, allocations: 0.49 GB / 0.7959 GB, free: 33.43 MB / 0.6231 GB " [Timeout remaining time 176] Using package Buildings with version 12.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatPumpGroupAirToWater,fileNamePrefix="Buildings_12_Buildings_Templates_Plants_HeatPumps_Components_Validation_HeatPumpGroupAirToWater",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatPumpGroupAirToWater,fileNamePrefix="Buildings_12_Buildings_Templates_Plants_HeatPumps_Components_Validation_HeatPumpGroupAirToWater",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002073/0.002073, allocations: 69.64 kB / 1.155 GB, free: 25.79 MB / 0.9044 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.338/0.3401, allocations: 176.1 MB / 1.327 GB, free: 1.969 MB / 1.014 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Interfaces/PartialController.mo:32:3-39:83:writable] Warning: Parameter ctlPlaAwNrv.nAirHan has no value, and is fixed during initialization (fixed=true), using available start value (start=0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Interfaces/PartialController.mo:40:3-47:83:writable] Warning: Parameter ctlPlaAwNrv.nEquZon has no value, and is fixed during initialization (fixed=true), using available start value (start=0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Interfaces/PartialController.mo:32:3-39:83:writable] Warning: Parameter ctlPlaAw.nAirHan has no value, and is fixed during initialization (fixed=true), using available start value (start=0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Interfaces/PartialController.mo:40:3-47:83:writable] Warning: Parameter ctlPlaAw.nEquZon has no value, and is fixed during initialization (fixed=true), using available start value (start=0) as default value. Notification: Performance of NFInst.instantiate(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatPumpGroupAirToWater): time 1.293/1.633, allocations: 438.4 MB / 1.755 GB, free: 27.02 MB / 1.295 GB Notification: Performance of NFInst.instExpressions: time 0.07235/1.705, allocations: 55.83 MB / 1.809 GB, free: 5.98 MB / 1.295 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01563/1.721, allocations: 481 kB / 1.81 GB, free: 5.98 MB / 1.295 GB Notification: Performance of NFTyping.typeComponents: time 0.01435/1.735, allocations: 5.789 MB / 1.815 GB, free: 2.352 MB / 1.295 GB Notification: Performance of NFTyping.typeBindings: time 0.03632/1.772, allocations: 11.64 MB / 1.827 GB, free: 9.285 MB / 1.311 GB Notification: Performance of NFTyping.typeClassSections: time 0.02558/1.797, allocations: 8.42 MB / 1.835 GB, free: 2.742 MB / 1.311 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:17:3-24:112:writable] Warning: Parameter datCtlPlaAwNrv.THeaWatSupSet_min has no value, and is fixed during initialization (fixed=true), using available start value (start=25.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:31:3-37:112:writable] Warning: Parameter datCtlPlaAwNrv.VHeaWatHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:46:3-51:112:writable] Warning: Parameter datCtlPlaAwNrv.capHeaHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:61:3-68:98:writable] Warning: Parameter datCtlPlaAwNrv.VHeaWatSec_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:96:3-104:45:writable] Warning: Parameter datCtlPlaAwNrv.dpHeaWatLocSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=1e5) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:105:3-115:37:writable] Warning: Parameter datCtlPlaAwNrv.yPumHeaWatPriSet has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:137:3-143:31:writable] Warning: Parameter datCtlPlaAwNrv.TChiWatSup_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=Buildings.Templates.Data.Defaults.TChiWatSup) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:144:3-150:112:writable] Warning: Parameter datCtlPlaAwNrv.TChiWatSupSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=15.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:157:3-163:112:writable] Warning: Parameter datCtlPlaAwNrv.VChiWatHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:172:3-177:112:writable] Warning: Parameter datCtlPlaAwNrv.capCooHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:187:3-194:98:writable] Warning: Parameter datCtlPlaAwNrv.VChiWatSec_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:226:3-234:45:writable] Warning: Parameter datCtlPlaAwNrv.dpChiWatLocSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=1e5) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:235:3-244:37:writable] Warning: Parameter datCtlPlaAwNrv.yPumChiWatPriSet has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:303:3-309:87:writable] Warning: Parameter datCtlPlaAwNrv.TChiWatSupHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=4.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:310:3-316:87:writable] Warning: Parameter datCtlPlaAwNrv.THeaWatSupHrc_max has no value, and is fixed during initialization (fixed=true), using available start value (start=60.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:317:3-322:87:writable] Warning: Parameter datCtlPlaAwNrv.COPHeaHrc_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=2.8) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:323:3-328:87:writable] Warning: Parameter datCtlPlaAwNrv.capCooHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:329:3-334:87:writable] Warning: Parameter datCtlPlaAwNrv.capHeaHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:17:3-24:112:writable] Warning: Parameter datCtlPlaAw.THeaWatSupSet_min has no value, and is fixed during initialization (fixed=true), using available start value (start=25.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:31:3-37:112:writable] Warning: Parameter datCtlPlaAw.VHeaWatHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:46:3-51:112:writable] Warning: Parameter datCtlPlaAw.capHeaHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:61:3-68:98:writable] Warning: Parameter datCtlPlaAw.VHeaWatSec_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:96:3-104:45:writable] Warning: Parameter datCtlPlaAw.dpHeaWatLocSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=1e5) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:105:3-115:37:writable] Warning: Parameter datCtlPlaAw.yPumHeaWatPriSet has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:144:3-150:112:writable] Warning: Parameter datCtlPlaAw.TChiWatSupSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=15.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:157:3-163:112:writable] Warning: Parameter datCtlPlaAw.VChiWatHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:172:3-177:112:writable] Warning: Parameter datCtlPlaAw.capCooHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:187:3-194:98:writable] Warning: Parameter datCtlPlaAw.VChiWatSec_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:226:3-234:45:writable] Warning: Parameter datCtlPlaAw.dpChiWatLocSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=1e5) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:235:3-244:37:writable] Warning: Parameter datCtlPlaAw.yPumChiWatPriSet has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:303:3-309:87:writable] Warning: Parameter datCtlPlaAw.TChiWatSupHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=4.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:310:3-316:87:writable] Warning: Parameter datCtlPlaAw.THeaWatSupHrc_max has no value, and is fixed during initialization (fixed=true), using available start value (start=60.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:317:3-322:87:writable] Warning: Parameter datCtlPlaAw.COPHeaHrc_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=2.8) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:323:3-328:87:writable] Warning: Parameter datCtlPlaAw.capCooHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:329:3-334:87:writable] Warning: Parameter datCtlPlaAw.capHeaHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:69:3-75:22:writable] Warning: Parameter datHpAwNrv.mChiWatHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:80:3-84:22:writable] Warning: Parameter datHpAwNrv.capCooHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:85:3-90:22:writable] Warning: Parameter datHpAwNrv.TChiWatSupHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=280.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:102:3-108:79:writable] Warning: Parameter datHpAwNrv.mSouWwHeaHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=datHpAwNrv.mHeaWatHp_flow_nominal) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:109:3-114:79:writable] Warning: Parameter datHpAwNrv.dpSouWwHeaHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=Buildings.Templates.Data.Defaults.dpChiWatChi) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:124:3-129:22:writable] Warning: Parameter datHpAwNrv.TSouCooHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=Buildings.Templates.Data.Defaults.TOutHpCoo) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:130:3-136:90:writable] Warning: Parameter datHpAwNrv.mSouWwCooHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=datHpAwNrv.mChiWatHp_flow_nominal) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:102:3-108:79:writable] Warning: Parameter datHpAw.mSouWwHeaHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=datHpAw.mHeaWatHp_flow_nominal) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:109:3-114:79:writable] Warning: Parameter datHpAw.dpSouWwHeaHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=Buildings.Templates.Data.Defaults.dpChiWatChi) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:130:3-136:90:writable] Warning: Parameter datHpAw.mSouWwCooHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=datHpAw.mChiWatHp_flow_nominal) as default value. Notification: Performance of NFFlatten.flatten: time 0.09581/1.893, allocations: 58.61 MB / 1.892 GB, free: 9.199 MB / 1.373 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Validation/HeatPumpGroupAirToWater.mo:346:3-347:80:writable] Error: Cannot connect expandable connector busHp with non-expandable connector busPla.hp. Notification: Performance of FrontEnd: time 0.009076/1.902, allocations: 3.508 MB / 1.896 GB, free: 5.602 MB / 1.373 GB " [Timeout remaining time 298] [Calling sys.exit(0), Time elapsed: 8.51308872498339] Failed to read output from testmodel.py, exit status != 0: 1.9089501000125892 1.92594603 -1.0 Calling exit ...