/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_12_Buildings.Fluid.DXSystems.Cooling.WaterSource.Examples.VariableSpeed_res.mat --tempDir=temp_Buildings_12_Buildings_Fluid_DXSystems_Cooling_WaterSource_Examples_VariableSpeed_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=400 --tolerance=1e-06 Buildings_12_Buildings_Fluid_DXSystems_Cooling_WaterSource_Examples_VariableSpeed.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.DXSystems.Cooling.WaterSource.Examples.VariableSpeed" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.DXSystems.Cooling.WaterSource.Examples.VariableSpeed" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.DXSystems.Cooling.WaterSource.Examples.VariableSpeed/model-ayrdkl7x" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.DXSystems.Cooling.WaterSource.Examples.VariableSpeed" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_12_Buildings_Fluid_DXSystems_Cooling_WaterSource_Examples_VariableSpeed.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_NLS | error | residualFunc371: Iteration variable ` ?Ëú` is inf or nan. LOG_ASSERT | debug | residualFunc371 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_NLS | error | residualFunc371: Iteration variable ` ?Ëú` is inf or nan. LOG_ASSERT | debug | residualFunc371 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_NLS | error | residualFunc371: Iteration variable ` ?Ëú` is inf or nan. LOG_ASSERT | debug | residualFunc371 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_NLS | error | residualFunc371: Iteration variable ` ?Ëú` is inf or nan. LOG_ASSERT | debug | residualFunc371 failed at time=0. | | | | For more information please use -lv LOG_NLS. warning: [fmi2Warning] Buildings_12_Buildings_Fluid_DXSystems_Cooling_WaterSource_Examples_VariableSpeed/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/DXSystems/Cooling/BaseClasses/Functions/warnIfPerformanceOutOfBounds.mo:18: *** Warning: DX coil performance curves at nominal conditions are outside of bounds. Capacity as a function of temperature is outside of bounds 0.9 to 1.1. The value of the curve fit is 1.2941 Check the coefficients of the function sta[1].perCur.capFunT. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((varSpeDX.eva.watVapEva.nomVal.gamma <= varSpeDX.eva.watVapEva.gammaMax)) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 0.393653, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 1.5 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00969167 - 0.0102426 = -0.00055089 | | | | QLat_flow_nominal = -4200 | | | | " info: Result file: Buildings_12_Buildings.Fluid.DXSystems.Cooling.WaterSource.Examples.VariableSpeed_res.mat (bufferSize=1) info: 3 warnings info: 0 errors