/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT_res.mat --tempDir=temp_Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT_fmu --startTime=0 --stopTime=603900 --stepSize=120.012 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT/model-ywdvm37y" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.fmu - startTime: 0.000000 - stopTime: 603900.000000 - tolerance: 0.000001 - stepSize: 120.012000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_STDOUT | info | ... loading "dat" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT/model-ywdvm37y/temp/0001_Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Resources/Data/Fluid/FixedResistances/Validation/PlugFlowPipes/PipeDataAIT151218.mos" info: Result file: Buildings_11_Buildings.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT_res.mat (bufferSize=1) info: Parameter model.root.Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.DataReader.delimiter will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.DataReader.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.DataReader.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.pipeDataAIT151218.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 15121.512000 | | | | ((noEvent(pip0.vol_b.dynBal.medium.T <= 403.15))) --> "In PlugFlowAIT.pip0.vol_b.dynBal.medium: Temperature T = 411.615 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 15121.512000 | | | | ((noEvent(pip0.vol_b.dynBal.medium.T <= 403.15))) --> "In PlugFlowAIT.pip0.vol_b.dynBal.medium: Temperature T = 411.613 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable switch1.u2 error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 5 errors