/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Fluid_Movers_Validation_FlowControlled_dpSystem_fmu --startTime=0 --stopTime=1 --stepSize=0.0004 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Fluid_Movers_Validation_FlowControlled_dpSystem.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.Movers.Validation.FlowControlled_dpSystem" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.Movers.Validation.FlowControlled_dpSystem" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.Movers.Validation.FlowControlled_dpSystem/model-ccs1zgai" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.Movers.Validation.FlowControlled_dpSystem" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: BuildingSystems_BuildingSystems_Fluid_Movers_Validation_FlowControlled_dpSystem.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.000400 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 0.750400 | | | | ((heaCoi1.m_flow > (-floConDp.vol.m_flow_small))) --> "In FlowControlled_dpSystem.floConDp.vol: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.000597353 | | | | " error: [fmi2logger] [fmi2Error] BuildingSystems_BuildingSystems_Fluid_Movers_Validation_FlowControlled_dpSystem/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.BuildingSystems_BuildingSystems_Fluid_Movers_Validation_FlowControlled_dpSystem" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 0.750400 | | | | ((heaCoi1.m_flow > (-floConDp.vol.m_flow_small))) --> "In FlowControlled_dpSystem.floConDp.vol: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.000597353 | | | | " error: [fmi2logger] [fmi2Error] BuildingSystems_BuildingSystems_Fluid_Movers_Validation_FlowControlled_dpSystem/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable zone4.use_C_flow error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 5 errors