/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Examples_Test_EnthalpyExchanger_fmu --startTime=0 --stopTime=7200 --stepSize=1 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Examples_Test_EnthalpyExchanger.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Examples.Test_EnthalpyExchanger" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Examples.Test_EnthalpyExchanger" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Examples.Test_EnthalpyExchanger/model-xp78624v" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Examples.Test_EnthalpyExchanger" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Examples_Test_EnthalpyExchanger.fmu - startTime: 0.000000 - stopTime: 7200.000000 - tolerance: 0.000001 - stepSize: 1.000000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Examples_Test_EnthalpyExchanger.senMasFraColIn.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Examples_Test_EnthalpyExchanger.senMasFraColOut.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Examples_Test_EnthalpyExchanger.senMasFraHotIn.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Examples_Test_EnthalpyExchanger.senMasFraHotOut.substanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Examples.Test_EnthalpyExchanger/447.fmutmp/sources/gc/memory_pool.c:100: pool_expand: Assertion `0 && "Attempt to allocate an unusually large memory. The memory management does not seem to be working as intended. Please create an issue on https://github.com/OpenModelica/OpenModelica/issues."` failed. fmi2DoStep: ##CVODE## -6 error occurred at time = 4002.error: [fmi2logger] [fmi2Fatal] AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Examples_Test_EnthalpyExchanger/logStatusFatal: fmi2DoStep: CVODE integrator step failed. error: [stepUntil] fmi2_doStep failed for FMU "model.root.AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Examples_Test_EnthalpyExchanger" error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 3 errors