/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Fluid_DistrictHeatingCooling_Demands_Examples_DHCSubstationHeatPumpChiller_fmu --startTime=0 --stopTime=86400 --stepSize=60 --timeout=50 --tolerance=1e-07 AixLib_AixLib_Fluid_DistrictHeatingCooling_Demands_Examples_DHCSubstationHeatPumpChiller.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.DistrictHeatingCooling.Demands.Examples.DHCSubstationHeatPumpChiller" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.DistrictHeatingCooling.Demands.Examples.DHCSubstationHeatPumpChiller" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.DistrictHeatingCooling.Demands.Examples.DHCSubstationHeatPumpChiller/model-v5o3hfwv" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.DistrictHeatingCooling.Demands.Examples.DHCSubstationHeatPumpChiller" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: AixLib_AixLib_Fluid_DistrictHeatingCooling_Demands_Examples_DHCSubstationHeatPumpChiller.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000000 - stepSize: 60.000000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-07 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumHea.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumHea: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumCoo: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 7260.000000 | | | | (((-DHCsubstationHeatingDirectCooling.pumHea.dp) <= 4e4)) --> "In DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumHea: Model operates with head -dp = 57385.5 Pa, | | | | exceeding the pressure allowed by the parameter DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumHea.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] AixLib_AixLib_Fluid_DistrictHeatingCooling_Demands_Examples_DHCSubstationHeatPumpChiller/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 7260.000000 | | | | (((-DHCsubstationHeatingDirectCooling.pumHea.dp) <= 4e4)) --> "In DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumHea: Model operates with head -dp = 57385.5 Pa, | | | | exceeding the pressure allowed by the parameter DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumHea.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] AixLib_AixLib_Fluid_DistrictHeatingCooling_Demands_Examples_DHCSubstationHeatPumpChiller/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 7320.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumCoo.dpMachine <= 4e4)) --> "In DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumCoo: Model operates with head -dp = 55419.6 Pa, | | | | exceeding the pressure allowed by the parameter DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumCoo.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] AixLib_AixLib_Fluid_DistrictHeatingCooling_Demands_Examples_DHCSubstationHeatPumpChiller/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.AixLib_AixLib_Fluid_DistrictHeatingCooling_Demands_Examples_DHCSubstationHeatPumpChiller" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 7320.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumCoo.dpMachine <= 4e4)) --> "In DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumCoo: Model operates with head -dp = 55419.6 Pa, | | | | exceeding the pressure allowed by the parameter DHCSubstationHeatPumpChiller.DHCsubstationHeatingDirectCooling.pumCoo.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] AixLib_AixLib_Fluid_DistrictHeatingCooling_Demands_Examples_DHCSubstationHeatPumpChiller/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable warmLine.verifyInputs error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 7 errors