Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.9024/0.9024, allocations: 153.8 MB / 173.4 MB, free: 4.945 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding") translateModel(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.0005604/0.0005604, allocations: 15.97 kB / 251.1 MB, free: 3.949 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2014/0.202, allocations: 33.36 MB / 284.5 MB, free: 2.152 MB / 222.1 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding): time 1.967/2.169, allocations: 319.4 MB / 0.5898 GB, free: 12.27 MB / 478.1 MB Notification: Performance of NFInst.instExpressions: time 0.2598/2.429, allocations: 196.2 MB / 0.7814 GB, free: 4.902 MB / 0.6387 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.003988/2.433, allocations: 39.88 kB / 0.7814 GB, free: 4.863 MB / 0.6387 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:178:3-180:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:181:3-183:56:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:194:3-196:48:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:80:3-81:83:writable] Warning: Connector C1vap is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:82:3-84:16:writable] Warning: Connector C2ex is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:85:3-87:24:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:88:3-90:17:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:95:3-97:17:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/Sink.mo:17:3-19:16:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/RefQ.mo:15:3-17:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/RefQ.mo:18:3-19:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/IdealCheckValve.mo:22:3-23:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/IdealCheckValve.mo:24:3-25:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:49:3-50:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:51:3-53:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.003208/2.436, allocations: 0.9418 MB / 0.7823 GB, free: 3.922 MB / 0.6387 GB Notification: Performance of NFTyping.typeBindings: time 0.006162/2.442, allocations: 2.067 MB / 0.7844 GB, free: 1.844 MB / 0.6387 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.0446/2.487, allocations: 13.75 MB / 0.7978 GB, free: 4.098 MB / 0.6544 GB Notification: Performance of NFFlatten.flatten: time 0.02894/2.516, allocations: 26.24 MB / 0.8234 GB, free: 9.789 MB / 0.6856 GB Notification: Performance of NFFlatten.resolveConnections: time 0.0133/2.529, allocations: 7.283 MB / 0.8305 GB, free: 2.422 MB / 0.6856 GB Notification: Performance of NFEvalConstants.evaluate: time 0.3607/2.89, allocations: 8.269 MB / 0.8386 GB, free: 20.38 MB / 0.6856 GB Notification: Performance of NFSimplifyModel.simplify: time 0.01773/2.908, allocations: 8.61 MB / 0.847 GB, free: 20.37 MB / 0.6856 GB Notification: Performance of NFPackage.collectConstants: time 0.007546/2.915, allocations: 1.797 MB / 0.8488 GB, free: 20.37 MB / 0.6856 GB Notification: Performance of NFFlatten.collectFunctions: time 0.0516/2.967, allocations: 23.03 MB / 0.8713 GB, free: 20.36 MB / 0.6856 GB Notification: Performance of NFScalarize.scalarize: time 0.009373/2.976, allocations: 5.883 MB / 0.877 GB, free: 20.08 MB / 0.6856 GB Notification: Performance of NFVerifyModel.verify: time 0.01901/2.995, allocations: 8.509 MB / 0.8853 GB, free: 18.21 MB / 0.6856 GB Notification: Performance of NFConvertDAE.convert: time 0.05681/3.052, allocations: 32.38 MB / 0.9169 GB, free: 10.68 MB / 0.6856 GB Notification: Performance of FrontEnd - DAE generated: time 6.843e-06/3.052, allocations: 4 kB / 0.9169 GB, free: 10.67 MB / 0.6856 GB Notification: Performance of FrontEnd: time 2.625e-06/3.052, allocations: 4.703 kB / 0.9169 GB, free: 10.67 MB / 0.6856 GB Notification: Performance of Transformations before backend: time 0.0008175/3.053, allocations: 0.5625 kB / 0.9169 GB, free: 10.67 MB / 0.6856 GB Error: Too few equations, under-determined system. The model has 3749 equation(s) and 3751 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/InstrumentationAndControl/Connectors.mo:52:5-52:22:writable] Warning: Variable regulation_Niveau.MesureDebitVapeur.signal does not have any remaining equation to be solved in. The original equations were: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/InstrumentationAndControl/Connectors.mo:52:5-52:22:writable] Warning: Variable regulation_Niveau.MesureDebitEau.signal does not have any remaining equation to be solved in. The original equations were: " [Timeout remaining time 657] [Calling sys.exit(0), Time elapsed: 4.794377359095961] Failed to read output from testmodel.py, exit status != 0: 3.359834693139419 3.375191113 0.31976566700000003 Calling exit ...