Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_12_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.002097/0.002097, allocations: 110.2 kB / 19.69 MB, free: 2.254 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002672/0.002672, allocations: 214 kB / 23.01 MB, free: 4.566 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.499/1.499, allocations: 230.6 MB / 256.8 MB, free: 8.012 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo): time 3.245/3.245, allocations: 0.49 GB / 0.7958 GB, free: 33.34 MB / 0.6231 GB " [Timeout remaining time 176] Using package Buildings with version 12.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|bus.hrc.y1|bus.hrc.y1Coo|bus.pumChiWatHrc.y1|bus.pumHeaWatHrc.y1|TChiWatLvg.T|inlChiWat.T|TSupSet.y|THeaWatLvg.T|inlHeaWat.T|hrc.hrc.chi.PLR2|hrc.hrc.chi.COP",fileNamePrefix="Buildings_12_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller") translateModel(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|bus.hrc.y1|bus.hrc.y1Coo|bus.pumChiWatHrc.y1|bus.pumHeaWatHrc.y1|TChiWatLvg.T|inlChiWat.T|TSupSet.y|THeaWatLvg.T|inlHeaWat.T|hrc.hrc.chi.PLR2|hrc.hrc.chi.COP",fileNamePrefix="Buildings_12_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller") [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.00204/0.00204, allocations: 74.14 kB / 1.155 GB, free: 25.47 MB / 0.9044 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3568/0.3588, allocations: 176.1 MB / 1.327 GB, free: 1.473 MB / 1.014 GB Notification: Performance of NFInst.instantiate(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller): time 0.1558/0.5147, allocations: 144.9 MB / 1.469 GB, free: 52 kB / 1.154 GB Notification: Performance of NFInst.instExpressions: time 0.07241/0.5871, allocations: 42.85 MB / 1.51 GB, free: 5.09 MB / 1.201 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01198/0.5991, allocations: 254.1 kB / 1.511 GB, free: 4.84 MB / 1.201 GB Notification: Performance of NFTyping.typeComponents: time 0.0147/0.6138, allocations: 4.729 MB / 1.515 GB, free: 96 kB / 1.201 GB Notification: Performance of NFTyping.typeBindings: time 0.02394/0.6377, allocations: 7.02 MB / 1.522 GB, free: 9.047 MB / 1.217 GB Notification: Performance of NFTyping.typeClassSections: time 0.01504/0.6527, allocations: 5.196 MB / 1.527 GB, free: 3.871 MB / 1.217 GB Notification: Performance of NFFlatten.flatten: time 0.0518/0.7045, allocations: 31.64 MB / 1.558 GB, free: 4.184 MB / 1.248 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Validation/HeatRecoveryChiller.mo:154:3-155:89:writable] Error: Cannot connect expandable connector busPumHeaWatHrc with non-expandable connector bus.pumHeaWatHrc. Notification: Performance of FrontEnd: time 0.002539/0.7071, allocations: 0.7631 MB / 1.559 GB, free: 3.371 MB / 1.248 GB " [Timeout remaining time 299] [Calling sys.exit(0), Time elapsed: 7.213938697008416] Failed to read output from testmodel.py, exit status != 0: 0.7156039870169479 0.7308829 -1.0 Calling exit ...