Environment - simulationEnvironment: startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.2 Regular simulation: ./ThermofluidStream_ThermofluidStream.Examples.ReverseHeatPump -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/Boundaries/PhaseSeparator.mo:41:3-41:139:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((accumulator.x >= 0.0 and accumulator.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= accumulator.x <= 1.0, has value: 1.28663" LOG_ASSERT | debug | Solving non-linear system 2665 failed at time=12.3022314231759. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 12.065863. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 80.200000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 80.200000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 80.200000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 80.200000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0531693s reading init.xml | | | | | | 0.00495686s reading info.xml | | | | | | 0.00152602s [ 0.0%] pre-initialization | | | | | | 0.0480197s [ 0.0%] initialization | | | | | | 0.0158464s [ 0.0%] steps | | | | | | 0.064353s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00563762s [ 0.0%] creating output-file | | | | | | 47.0488s [ 17.3%] event-handling | | | | | | 0.0440736s [ 0.0%] overhead | | | | | | 224.174s [ 82.6%] simulation | | | | | | 271.402s [100.0%] total | | | | | events | | | | | | 10 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 3769 steps taken | | | | | | 5872 calls of functionODE | | | | | | 658 evaluations of jacobian | | | | | | 332 error test failures | | | | | | 8 convergence test failures | | | | | | 158.424s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.