Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/CentrifugalPump.mo:94:3-94:43:writable] | | | | The following assertion has been violated at time 212.800000 | | | | ((centrifugalPump1.hn >= 0.0)) --> "Variable violating min constraint: 0.0 <= centrifugalPump1.hn, has value: -0.00174059" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00615369s reading init.xml | | | | | | 0.000498184s reading info.xml | | | | | | 7.4089e-05s [ 0.0%] pre-initialization | | | | | | 0.00363486s [ 0.2%] initialization | | | | | | 0.00065053s [ 0.0%] steps | | | | | | 0.00411347s [ 0.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.786131s [ 41.4%] event-handling | | | | | | 0.0162413s [ 0.9%] overhead | | | | | | 1.08674s [ 57.3%] simulation | | | | | | 1.89759s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 3 time events | | | | | solver: dassl | | | | | | 1984 steps taken | | | | | | 2957 calls of functionODE | | | | | | 370 evaluations of jacobian | | | | | | 180 error test failures | | | | | | 0 convergence test failures | | | | | | 0.24477s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.