Environment - simulationEnvironment: startTime=0 stopTime=0.1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.0002 Regular simulation: ./Modelica_4.1.0_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTapmPulse.ThyristorCenterTapmPulse_R -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00628909s reading init.xml | | | | | | 0.000503524s reading info.xml | | | | | | 0.000644037s [ 3.6%] pre-initialization | | | | | | 0.000188323s [ 1.1%] initialization | | | | | | 1.5169e-05s [ 0.1%] steps | | | | | | 0.00190946s [ 10.7%] solver (excl. callbacks) | | | | | | 0.000467465s [ 2.6%] creating output-file | | | | | | 0.00727326s [ 40.9%] event-handling | | | | | | 0.00012894s [ 0.7%] overhead | | | | | | 0.00716299s [ 40.3%] simulation | | | | | | 0.0177896s [100.0%] total | | | | | events | | | | | | 89 state events | | | | | | 15 time events | | | | | solver: dassl | | | | | | 2218 steps taken | | | | | | 2682 calls of functionODE | | | | | | 1118 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0011421s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.