Environment - simulationEnvironment: startTime=0 stopTime=864000 tolerance=1e-06 numberOfIntervals=2500 stepSize=345.6 Regular simulation: ./Buildings_12_Buildings.ThermalZones.Detailed.FLEXLAB.Rooms.Examples.X3BWithRadiantFloor -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_STDOUT | info | ... loading "airCon" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Resources/Data/ThermalZones/Detailed/FLEXLAB/Rooms/Examples/X3AWithRadiantFloor.txt" LOG_STDOUT | info | ... loading "airCon" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Resources/Data/ThermalZones/Detailed/FLEXLAB/Rooms/Examples/X3AWithRadiantFloor.txt" LOG_STDOUT | info | ... loading "airCon" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Resources/Data/ThermalZones/Detailed/FLEXLAB/Rooms/Examples/X3AWithRadiantFloor.txt" LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.011863. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | info | Too many warnings, reached display limit of 3. Suppressing further warning messages of the same type. LOG_STDOUT | info | Change limit with simulation flag -lvMaxWarn= LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 3.024965. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 33.393245. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 57.687868. That might raise performance issues, for more information use -lv LOG_LS. LOG_STDOUT | info | Too many warnings, reached display limit of 3. Suppressing further warning messages of the same type. LOG_STDOUT | info | Change limit with simulation flag -lvMaxWarn= LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.381958s reading init.xml | | | | | | 0.0396243s reading info.xml | | | | | | 0.0085364s [ 0.2%] pre-initialization | | | | | | 0.0378991s [ 0.8%] initialization | | | | | | 0.000220434s [ 0.0%] steps | | | | | | 0.678665s [ 14.9%] solver (excl. callbacks) | | | | | | 0.0240237s [ 0.5%] creating output-file | | | | | | 0.0144101s [ 0.3%] event-handling | | | | | | 0.036464s [ 0.8%] overhead | | | | | | 3.76684s [ 82.5%] simulation | | | | | | 4.56706s [100.0%] total | | | | | events | | | | | | 21 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 11287 steps taken | | | | | | 18418 calls of functionODE | | | | | | 2571 evaluations of jacobian | | | | | | 1426 error test failures | | | | | | 0 convergence test failures | | | | | | 2.58179s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.