Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_12_Buildings.Templates.ZoneEquipment.Validation.VAVBoxReheat.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001375/0.001375, allocations: 104.7 kB / 16.45 MB, free: 6.449 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002075/0.002075, allocations: 210.4 kB / 19.43 MB, free: 3.637 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.567/1.567, allocations: 230.6 MB / 252.8 MB, free: 9.125 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo): time 3.304/3.304, allocations: 0.4899 GB / 0.7916 GB, free: 33.38 MB / 0.6231 GB " [Timeout remaining time 176] Using package Buildings with version 12.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.ZoneEquipment.Validation.VAVBoxReheat,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|VAVBox_1.bus.TAirSup|VAVBox_1.bus.TAirDis|VAVBox_1.bus.TZon|VAVBox_1.damVAV.m_flow",fileNamePrefix="Buildings_12_Buildings.Templates.ZoneEquipment.Validation.VAVBoxReheat") translateModel(Buildings.Templates.ZoneEquipment.Validation.VAVBoxReheat,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|VAVBox_1.bus.TAirSup|VAVBox_1.bus.TAirDis|VAVBox_1.bus.TZon|VAVBox_1.damVAV.m_flow",fileNamePrefix="Buildings_12_Buildings.Templates.ZoneEquipment.Validation.VAVBoxReheat") [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002335/0.002335, allocations: 68.91 kB / 1.149 GB, free: 26.13 MB / 0.9044 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5023/0.5046, allocations: 176.1 MB / 1.321 GB, free: 2.824 MB / 1.014 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/ZoneEquipment/Validation/UserProject/Data/AllSystems.mo:9:3-31:48:writable] Warning: Components are deprecated in class. Notification: Performance of NFInst.instantiate(Buildings.Templates.ZoneEquipment.Validation.VAVBoxReheat): time 2.174/2.679, allocations: 0.7888 GB / 2.11 GB, free: 2.781 MB / 1.592 GB Notification: Performance of NFInst.instExpressions: time 0.1472/2.826, allocations: 74.14 MB / 2.182 GB, free: 8.465 MB / 1.67 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0306/2.857, allocations: 0.69 MB / 2.183 GB, free: 7.77 MB / 1.67 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/DXSystems/Cooling/AirSource/Data/Generic/DXCoil.mo:21:3-23:53:writable] Error: Could not evaluate structural parameter (or constant): VAVBox_1.dat.coiHea.datCoi.nSta which gives dimensions of array: sta. Array dimensions must be known at compile time. Notification: Performance of FrontEnd: time 0.005121/2.862, allocations: 1.181 MB / 2.184 GB, free: 6.582 MB / 1.67 GB " [Timeout remaining time 297] [Calling sys.exit(0), Time elapsed: 9.914325456134975] Failed to read output from testmodel.py, exit status != 0: 2.87119155889377 2.884671875 -1.0 Calling exit ...