Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.Examples.Steam.SingleBoiler -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (bld[1].pumCNR.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or bld[1].pumCNR.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in SingleBoiler.bld[1].pumCNR: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bld[1].pumCNR.per.haveWMot_nominal or not (bld[1].pumCNR.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or bld[1].pumCNR.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in SingleBoiler.bld[1].pumCNR: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (bld[2].pumCNR.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or bld[2].pumCNR.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in SingleBoiler.bld[2].pumCNR: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (bld[2].pumCNR.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or bld[2].pumCNR.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in SingleBoiler.bld[2].pumCNR: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (bld[3].pumCNR.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or bld[3].pumCNR.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in SingleBoiler.bld[3].pumCNR: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (bld[3].pumCNR.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or bld[3].pumCNR.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in SingleBoiler.bld[3].pumCNR: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Experimental/DHC/Loads/Steam/BaseClasses/ValveSelfActing.mo:42:3-44:88:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bld[3].prv.dpSet.u2 > 0.0)) --> "pb_nominal is set higher than the upstream pressure in SingleBoiler.bld[3].prv, which results in a negative pressure drop. | | | | This is not typical of real systems and should be verified." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Experimental/DHC/Loads/Steam/BaseClasses/ValveSelfActing.mo:42:3-44:88:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bld[2].prv.dpSet.u2 > 0.0)) --> "pb_nominal is set higher than the upstream pressure in SingleBoiler.bld[2].prv, which results in a negative pressure drop. | | | | This is not typical of real systems and should be verified." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Experimental/DHC/Loads/Steam/BaseClasses/ValveSelfActing.mo:42:3-44:88:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bld[1].prv.dpSet.u2 > 0.0)) --> "pb_nominal is set higher than the upstream pressure in SingleBoiler.bld[1].prv, which results in a negative pressure drop. | | | | This is not typical of real systems and should be verified." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Media/Steam.mo:26:5-26:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bld[1].sta_a.T >= 1.0 and bld[1].sta_a.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= bld[1].sta_a.T <= 1e4, has value: -918.506" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Media/Steam.mo:26:5-26:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bld[2].sta_a.T >= 1.0 and bld[2].sta_a.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= bld[2].sta_a.T <= 1e4, has value: -918.506" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Media/Steam.mo:26:5-26:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bld[3].sta_a.T >= 1.0 and bld[3].sta_a.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= bld[3].sta_a.T <= 1e4, has value: -918.506" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0650024s reading init.xml | | | | | | 0.0055785s reading info.xml | | | | | | 0.00198665s [ 0.0%] pre-initialization | | | | | | 0.21711s [ 0.2%] initialization | | | | | | 1.09345s [ 0.9%] steps | | | | | | 0.0351694s [ 0.0%] solver (excl. callbacks) | | | | | | 0.0267691s [ 0.0%] creating output-file | | | | | | 39.3173s [ 31.0%] event-handling | | | | | | 0.0397572s [ 0.0%] overhead | | | | | | 86.1766s [ 67.9%] simulation | | | | | | 126.908s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 461 steps taken | | | | | | 729 calls of functionODE | | | | | | 154 evaluations of jacobian | | | | | | 50 error test failures | | | | | | 5 convergence test failures | | | | | | 45.2435s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.