Environment - simulationEnvironment: startTime=5.9616e+06 stopTime=6.5664e+06 tolerance=1e-05 numberOfIntervals=5040 stepSize=120 Regular simulation: ./AixLib_AixLib.Systems.ModularAHU.Examples.DemandControlledAHU -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | ... loading "internalGains" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Resources/LowOrder_ExampleData/SIA2024_SingleOffice_week.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 5961600.000000 | | | | ((genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DemandControlledAHU.genericAHU.fanSup: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 5961600.000000 | | | | ((genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DemandControlledAHU.genericAHU.fanRet: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Interfaces/ConservationEquation.mo:107:3-108:46:writable] | | | | The following assertion has been violated at time 5961600.221474 | | | | ((genericAHU.dynamicHX.vol2[2].dynBal.mC[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.dynamicHX.vol2[2].dynBal.mC[1], has value: -1.45077e-25" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Interfaces/ConservationEquation.mo:111:3-112:38:writable] | | | | The following assertion has been violated at time 5961600.221474 | | | | ((genericAHU.dynamicHX.vol2[2].dynBal.C[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.dynamicHX.vol2[2].dynBal.C[1], has value: -9.67181e-27" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:31:3-33:69:writable] | | | | The following assertion has been violated at time 5961600.658808 | | | | ((genericAHU.preheater.hydraulicModule.valve.y_actual >= 0.0 and genericAHU.preheater.hydraulicModule.valve.y_actual <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.preheater.hydraulicModule.valve.y_actual <= 1.0, has value: -2.12226e-23" LOG_STDOUT | warning | Removed more then one event from spatialDistribution. Step size to big! LOG_STDOUT | warning | time: 5962977.941533, spatialDistribution index: 25, number of events: 4 LOG_STDOUT | warning | Removed more then one event from spatialDistribution. Step size to big! LOG_STDOUT | warning | time: 5962977.941533, spatialDistribution index: 24, number of events: 3 LOG_STDOUT | warning | Removed more then one event from spatialDistribution. Step size to big! LOG_STDOUT | warning | time: 5962989.289172, spatialDistribution index: 33, number of events: 4 LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:31:3-33:69:writable] | | | | The following assertion has been violated at time 5963400.000000 | | | | ((genericAHU.cooler.hydraulicModule.valve.y_actual >= 0.0 and genericAHU.cooler.hydraulicModule.valve.y_actual <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.cooler.hydraulicModule.valve.y_actual <= 1.0, has value: -1.46832e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:22:3-29:26:writable] | | | | The following assertion has been violated at time 5963760.000000 | | | | ((genericAHU.cooler.hydraulicModule.valve.res3.y >= 0.0 and genericAHU.cooler.hydraulicModule.valve.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.cooler.hydraulicModule.valve.res3.y <= 1.0, has value: 1"