/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_TransiEnt_TransiEnt_Storage_Heat_HotWaterStorage_L2_Check_Check_HotWaterStorage_L2_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --timeout=50 --tolerance=1e-06 TransiEnt_TransiEnt_Storage_Heat_HotWaterStorage_L2_Check_Check_HotWaterStorage_L2.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Storage.Heat.HotWaterStorage_L2.Check.Check_HotWaterStorage_L2" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Storage.Heat.HotWaterStorage_L2.Check.Check_HotWaterStorage_L2" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Storage.Heat.HotWaterStorage_L2.Check.Check_HotWaterStorage_L2/model-9uwrcyai" info: *** FMU Simulation Info *** - model: model (model exchange) - path: TransiEnt_TransiEnt_Storage_Heat_HotWaterStorage_L2_Check_Check_HotWaterStorage_L2.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000001 - stepSize: 34.560000 LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_INIT | error | The initialization problem is inconsistent due to the following equation: 0 != -56.7527 = $START.Storage.k_pipe_gen - Storage.k_pipe_gen error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Storage.Heat.HotWaterStorage_L2.Check.Check_HotWaterStorage_L2/model-9uwrcyai/temp/0001_TransiEnt_TransiEnt_Storage_Heat_HotWaterStorage_L2_Check_Check_HotWaterStorage_L2/logFmi2Call: fmi2EnterInitializationMode: failed error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.TransiEnt_TransiEnt_Storage_Heat_HotWaterStorage_L2_Check_Check_HotWaterStorage_L2" error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Storage.Heat.HotWaterStorage_L2.Check.Check_HotWaterStorage_L2/model-9uwrcyai/temp/0001_TransiEnt_TransiEnt_Storage_Heat_HotWaterStorage_L2_Check_Check_HotWaterStorage_L2/logStatusError: fmi2Terminate: Illegal model exchange call sequence. fmi2Terminate is not allowed in model_state_error state. error: [terminate] Termination of system "TransiEnt_TransiEnt_Storage_Heat_HotWaterStorage_L2_Check_Check_HotWaterStorage_L2" failed error: [terminate] Termination of system "model.root" failed error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Storage.Heat.HotWaterStorage_L2.Check.Check_HotWaterStorage_L2/model-9uwrcyai/temp/0001_TransiEnt_TransiEnt_Storage_Heat_HotWaterStorage_L2_Check_Check_HotWaterStorage_L2/logStatusError: fmi2Terminate: Illegal model exchange call sequence. fmi2Terminate is not allowed in model_state_error state. error: [terminate] Termination of system "TransiEnt_TransiEnt_Storage_Heat_HotWaterStorage_L2_Check_Check_HotWaterStorage_L2" failed error: [terminate] Termination of system "model.root" failed info: 2 warnings info: 10 errors