/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer_fmu --startTime=0 --stopTime=36000 --stepSize=14.4 --timeout=50 --tolerance=1e-06 TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Producer.Gas.Electrolyzer.Check.ComparisonOfElectrolyzer" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Producer.Gas.Electrolyzer.Check.ComparisonOfElectrolyzer" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Producer.Gas.Electrolyzer.Check.ComparisonOfElectrolyzer/model-cemvq5dr" info: *** FMU Simulation Info *** - model: model (model exchange) - path: TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.fmu - startTime: 0.000000 - stopTime: 36000.000000 - tolerance: 0.000001 - stepSize: 14.400000 LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi5.gas_pT.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi5.gas_pT.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi5.gas_pT.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi5.gas_pT.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi5.gas_pT.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi5.gas_pT.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi5.gas_pT.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi5.gas_pT.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi5.gas_pT.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi5.gas_pT.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi5.gas_pT.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi5.gas_pT.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer5.vleFluidH2.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer5.vleFluidH2.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer5.vleFluidH2.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer5.vleFluidH2.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer5.vleFluidH2.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer5.vleFluidH2.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer5.vleFluidH2.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer5.vleFluidH2.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer5.vleFluidH2.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer5.vleFluidH2.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer5.vleFluidH2.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer5.vleFluidH2.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi4.gas_pT.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi4.gas_pT.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi4.gas_pT.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi4.gas_pT.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi4.gas_pT.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi4.gas_pT.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi4.gas_pT.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi4.gas_pT.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi4.gas_pT.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi4.gas_pT.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi4.gas_pT.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi4.gas_pT.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer4.vleFluidH2.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer4.vleFluidH2.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer4.vleFluidH2.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer4.vleFluidH2.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer4.vleFluidH2.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer4.vleFluidH2.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer4.vleFluidH2.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer4.vleFluidH2.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer4.vleFluidH2.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer4.vleFluidH2.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer4.vleFluidH2.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer4.vleFluidH2.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi3.gas_pT.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi3.gas_pT.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi3.gas_pT.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi3.gas_pT.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi3.gas_pT.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi3.gas_pT.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi3.gas_pT.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi3.gas_pT.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi3.gas_pT.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi3.gas_pT.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi3.gas_pT.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi3.gas_pT.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer3.vleFluidH2.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer3.vleFluidH2.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer3.vleFluidH2.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer3.vleFluidH2.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer3.vleFluidH2.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer3.vleFluidH2.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer3.vleFluidH2.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer3.vleFluidH2.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer3.vleFluidH2.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer3.vleFluidH2.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer3.vleFluidH2.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer3.vleFluidH2.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi2.gas_pT.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi2.gas_pT.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi2.gas_pT.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi2.gas_pT.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi2.gas_pT.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi2.gas_pT.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi2.gas_pT.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi2.gas_pT.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi2.gas_pT.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi2.gas_pT.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi2.gas_pT.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi2.gas_pT.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer2.vleFluidH2.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer2.vleFluidH2.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer2.vleFluidH2.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer2.vleFluidH2.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer2.vleFluidH2.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer2.vleFluidH2.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer2.vleFluidH2.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer2.vleFluidH2.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer2.vleFluidH2.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer2.vleFluidH2.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer2.vleFluidH2.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer2.vleFluidH2.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi1.gas_pT.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi1.gas_pT.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi1.gas_pT.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi1.gas_pT.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi1.gas_pT.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi1.gas_pT.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi1.gas_pT.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi1.gas_pT.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi1.gas_pT.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi1.gas_pT.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi1.gas_pT.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi1.gas_pT.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi.gas_pT.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi.gas_pT.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi.gas_pT.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi.gas_pT.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi.gas_pT.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi.gas_pT.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi.gas_pT.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi.gas_pT.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi.gas_pT.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi.gas_pT.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boundary_pTxi.gas_pT.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundary_pTxi.gas_pT.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer1.vleFluidH2.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer1.vleFluidH2.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer1.vleFluidH2.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer1.vleFluidH2.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer1.vleFluidH2.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer1.vleFluidH2.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer1.vleFluidH2.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer1.vleFluidH2.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer1.vleFluidH2.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer1.vleFluidH2.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer1.vleFluidH2.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer1.vleFluidH2.VLE.T_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:4:3-4:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer.vleFluidH2.VLE.d_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer.vleFluidH2.VLE.d_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:5:3-5:43:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer.vleFluidH2.VLE.d_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer.vleFluidH2.VLE.d_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:8:3-8:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer.vleFluidH2.VLE.p_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer.vleFluidH2.VLE.p_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:9:3-9:53:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer.vleFluidH2.VLE.p_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer.vleFluidH2.VLE.p_v, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:12:3-12:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer.vleFluidH2.VLE.T_l >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer.vleFluidH2.VLE.T_l, has value: -1e+300" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLERecord.mo:13:3-13:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((electrolyzer.vleFluidH2.VLE.T_v >= 0.0)) --> "Variable violating min constraint: 0.0 <= electrolyzer.vleFluidH2.VLE.T_v, has value: -1e+300" info: maximum step size for 'model.root': 14.400000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi.gasPort.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi.gasPort.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi1.gasPort.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi1.gasPort.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi1.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi1.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi2.gasPort.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi2.gasPort.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi2.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi2.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi3.gasPort.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi3.gasPort.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi3.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi3.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi4.gasPort.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi4.gasPort.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi4.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi4.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi5.gasPort.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi5.gasPort.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi5.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.boundary_pTxi5.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer.EfficiencyCurve_Inverter.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer.EfficiencyCurve_Inverter.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer.gasPortOut.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer.gasPortOut.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer.summary.gasPortOut.mediumModel.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer.summary.gasPortOut.mediumModel.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer.vleFluidH2.vleFluidType.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer.vleFluidH2.vleFluidType.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer1.gasPortOut.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer1.gasPortOut.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer1.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer1.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer1.summary.gasPortOut.mediumModel.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer1.summary.gasPortOut.mediumModel.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer1.vleFluidH2.vleFluidType.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer1.vleFluidH2.vleFluidType.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.EfficiencyCurve_Inverter.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.EfficiencyCurve_Inverter.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.fluidPortIn.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.fluidPortIn.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.fluidPortOut.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.fluidPortOut.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.gasPortOut.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.gasPortOut.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.heatflow_L1_idContrMFlow_temp.fluidOut.vleFluidType.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.heatflow_L1_idContrMFlow_temp.fluidOut.vleFluidType.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.heatflow_L1_idContrMFlow_temp.fluidPortIn.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.heatflow_L1_idContrMFlow_temp.fluidPortIn.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.heatflow_L1_idContrMFlow_temp.fluidPortOut.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.heatflow_L1_idContrMFlow_temp.fluidPortOut.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.heatflow_L1_idContrMFlow_temp.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.heatflow_L1_idContrMFlow_temp.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.summary.gasPortOut.mediumModel.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.summary.gasPortOut.mediumModel.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.vleFluidH2.vleFluidType.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer2.vleFluidH2.vleFluidType.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.fluidPortIn.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.fluidPortIn.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.fluidPortOut.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.fluidPortOut.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.gasPortOut.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.gasPortOut.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.heatflow_L1_idContrMFlow_temp.fluidOut.vleFluidType.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.heatflow_L1_idContrMFlow_temp.fluidOut.vleFluidType.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.heatflow_L1_idContrMFlow_temp.fluidPortIn.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.heatflow_L1_idContrMFlow_temp.fluidPortIn.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.heatflow_L1_idContrMFlow_temp.fluidPortOut.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.heatflow_L1_idContrMFlow_temp.fluidPortOut.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.heatflow_L1_idContrMFlow_temp.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.heatflow_L1_idContrMFlow_temp.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.summary.gasPortOut.mediumModel.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.summary.gasPortOut.mediumModel.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.vleFluidH2.vleFluidType.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer3.vleFluidH2.vleFluidType.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer4.EfficiencyCurve_Inverter.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer4.EfficiencyCurve_Inverter.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer4.gasPortOut.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer4.gasPortOut.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer4.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer4.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer4.summary.gasPortOut.mediumModel.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer4.summary.gasPortOut.mediumModel.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer4.vleFluidH2.vleFluidType.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer4.vleFluidH2.vleFluidType.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer5.gasPortOut.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer5.gasPortOut.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer5.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer5.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer5.summary.gasPortOut.mediumModel.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer5.summary.gasPortOut.mediumModel.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer5.vleFluidH2.vleFluidType.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.electrolyzer5.vleFluidH2.vleFluidType.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.Variable_Ground_Temperature.absolute_path will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.Variable_Ground_Temperature.complete_relative_path will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.Variable_Ground_Temperature.environment_variable_name will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.Variable_Ground_Temperature.genericFileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.Variable_Ground_Temperature.relativepath will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.Variable_Ground_Temperature.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.airModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.electricityPrice.MSL_combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.electricityPrice.MSL_combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.electricityPrice.absolute_path will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.electricityPrice.complete_relative_path will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.electricityPrice.environment_variable_name will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.electricityPrice.genericFileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.electricityPrice.relativepath will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.electricityPrice.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.exhaustGasModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.exhaustGasModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.exhaustGasModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.exhaustGasModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.exhaustGasModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.exhaustGasModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.exhaustGasModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.exhaustGasModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.exhaustGasModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.exhaustGasModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.flueGasModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.fluid1.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.fluid1.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.fluid2.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.fluid2.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.fluid3.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.fluid3.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel1.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel1.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel1.vleFluidNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel1.vleFluidNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel1.vleFluidNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel1.vleFluidNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel1.vleFluidNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel1.vleFluidNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel2.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel2.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel2.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel2.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel2.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel2.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel2.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel2.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel3.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel3.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel4.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel4.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel4.vleFluidNames[2] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel4.vleFluidNames[3] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.gasModel4.vleFluidNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[1] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[2] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[3] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[4] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[5] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[6] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[7] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[8] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[9] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[10] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[11] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[12] will not be stored in the result file, because the signal type is not supported info: Parameter model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.generationPark.index[13] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.refrigerantFluid1.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.simCenter.refrigerantFluid1.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink1.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink1.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink1.steam_a.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink1.steam_a.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink2.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink2.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink2.steam_a.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink2.steam_a.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink3.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink3.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink3.steam_a.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink3.steam_a.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink8.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink8.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink8.steam_a.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.sink8.steam_a.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor.port.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor.port.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor1.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor1.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor1.port.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor1.port.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor2.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor2.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor2.port.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor2.port.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor3.medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor3.medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor3.port.Medium.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer.temperatureSensor3.port.Medium.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | division by zero at time 1800.0000001802, (a=45000) / (b=0), where divisor b expression is: electrolyzer3.P_el error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Producer.Gas.Electrolyzer.Check.ComparisonOfElectrolyzer/model-cemvq5dr/temp/0001_TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer" LOG_ASSERT | debug | division by zero at time 1800.0000001802, (a=45000) / (b=0), where divisor b expression is: electrolyzer3.P_el error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Producer.Gas.Electrolyzer.Check.ComparisonOfElectrolyzer/model-cemvq5dr/temp/0001_TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable electrolyzer4.temperature.cooling_PID.time_lag_I_activation.u LOG_ASSERT | debug | division by zero at time 1814.400000000004, (a=45000) / (b=0), where divisor b expression is: electrolyzer3.P_el error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Producer.Gas.Electrolyzer.Check.ComparisonOfElectrolyzer/model-cemvq5dr/temp/0001_TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStepCVODE] fmi2_completedIntegratorStep failed for FMU "model.root.TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer" warning: Bad return code at time 1814.400000 LOG_ASSERT | debug | division by zero at time 1814.400000000004, (a=45000) / (b=0), where divisor b expression is: electrolyzer3.P_el error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Producer.Gas.Electrolyzer.Check.ComparisonOfElectrolyzer/model-cemvq5dr/temp/0001_TransiEnt_TransiEnt_Producer_Gas_Electrolyzer_Check_ComparisonOfElectrolyzer/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable electrolyzer4.temperature.cooling_PID.time_lag_I_activation.u error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 249 NumRhsEvals = 313 NumLinSolvSetups = 48 NumNonlinSolvIters = 312 NumNonlinSolvConvFails = 0 NumErrTestFails = 12 info: 3 warnings info: 9 errors