Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.002169/0.002169, allocations: 104 kB / 16.45 MB, free: 6.449 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002795/0.002795, allocations: 210.4 kB / 19.43 MB, free: 3.637 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.518/1.518, allocations: 230.6 MB / 252.8 MB, free: 8.984 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.8185/0.8185, allocations: 100.8 MB / 409.7 MB, free: 4.266 MB / 318.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Processes_Tests_CentrifugalPumpCharacteristics",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Processes_Tests_CentrifugalPumpCharacteristics",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.00251/0.00251, allocations: 86.38 kB / 0.559 GB, free: 35.82 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1443/0.1468, allocations: 74.58 MB / 0.6319 GB, free: 8.25 MB / 478.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics): time 0.0644/0.2112, allocations: 54.28 MB / 0.6849 GB, free: 1.789 MB / 0.5137 GB Notification: Performance of NFInst.instExpressions: time 0.03652/0.2478, allocations: 26.62 MB / 0.7109 GB, free: 7.078 MB / 0.545 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001465/0.2492, allocations: 55.56 kB / 0.7109 GB, free: 7.023 MB / 0.545 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/CentrifugalPump/Measurements/GenericPump.mo:9:41-9:59:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/CentrifugalPump/Measurements/GenericPump.mo:9:3-10:50:writable] Error: Non-array modification '\"m3/h\"' for array component 'displayUnit', possibly due to missing 'each'. Notification: Performance of FrontEnd: time 0.001238/0.2505, allocations: 278.4 kB / 0.7112 GB, free: 6.75 MB / 0.545 GB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.8323160519939847] Failed to read output from testmodel.py, exit status != 0: 0.2573894319939427 0.272885175 -1.0 Calling exit ...