/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_dev_ThermofluidStream.FlowControl.Tests.Switch_res.mat --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch_fmu --startTime=0 --stopTime=10 --stepSize=0.01 --timeout=1200 --tolerance=1e-06 ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.FlowControl.Tests.Switch" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.FlowControl.Tests.Switch" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermofluidStream_dev_ThermofluidStream.FlowControl.Tests.Switch/model-88izej5d" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.fmu - startTime: 0.000000 - stopTime: 10.000000 - tolerance: 0.000001 - stepSize: 0.010000 info: maximum step size for 'model.root': 0.010000 info: Result file: ThermofluidStream_dev_ThermofluidStream.FlowControl.Tests.Switch_res.mat (bufferSize=1) info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.sink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.sink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.sink1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.sink1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.sink2.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.sink2.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.sink3.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.sink3.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source2.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source2.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source2.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_Switch.source2.displayPos4 will not be stored in the result file, because the signal type is not supported [CVODE ERROR] CVode At t = 0.5 and h = 1e-12, the error test failed repeatedly or with |h| = hmin. error: [doStepCVODE] CVode failed with flag = -3 warning: Bad return code at time 0.500000 error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 24 NumLinSolvSetups = 7 NumNonlinSolvIters = 20 NumNonlinSolvConvFails = 0 NumErrTestFails = 7 info: 3 warnings info: 2 errors