Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankSelfDraining.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001879/0.001879, allocations: 102.1 kB / 16.45 MB, free: 6.5 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002269/0.002269, allocations: 210.4 kB / 19.43 MB, free: 3.656 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.518/1.518, allocations: 230.6 MB / 252.8 MB, free: 8.938 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.8058/0.8058, allocations: 100.3 MB / 409.1 MB, free: 5.02 MB / 318.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Boundaries.Tests.TankSelfDraining,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Boundaries_Tests_TankSelfDraining",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Boundaries.Tests.TankSelfDraining,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Boundaries_Tests_TankSelfDraining",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002505/0.002505, allocations: 84.25 kB / 0.5582 GB, free: 36.07 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1201/0.1226, allocations: 74.41 MB / 0.6309 GB, free: 9.176 MB / 478.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Boundaries.Tests.TankSelfDraining): time 0.5867/0.7093, allocations: 240.5 MB / 0.8657 GB, free: 2.18 MB / 0.6075 GB Notification: Performance of NFInst.instExpressions: time 0.01483/0.7242, allocations: 10.08 MB / 0.8755 GB, free: 9.508 MB / 0.6231 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001184/0.7254, allocations: 39.62 kB / 0.8756 GB, free: 9.469 MB / 0.6231 GB Notification: Performance of NFTyping.typeComponents: time 0.00198/0.7273, allocations: 0.5828 MB / 0.8762 GB, free: 8.883 MB / 0.6231 GB Notification: Performance of NFTyping.typeBindings: time 0.007269/0.7346, allocations: 2.672 MB / 0.8788 GB, free: 6.199 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.002758/0.7374, allocations: 0.981 MB / 0.8797 GB, free: 5.223 MB / 0.6231 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.199417664902285] Failed to read output from testmodel.py, exit status != 0: 0.7438404129352421 0.758303497 -1.0 Calling exit ...