/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_ThermofluidStream.Processes.Tests.Compressor_res.mat --tempDir=temp_ThermofluidStream_ThermofluidStream_Processes_Tests_Compressor_fmu --startTime=0 --stopTime=30 --stepSize=0.03 --timeout=1200 --tolerance=1e-06 ThermofluidStream_ThermofluidStream_Processes_Tests_Compressor.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.Processes.Tests.Compressor" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.Processes.Tests.Compressor" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.Processes.Tests.Compressor/model-eywjvwwy" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermofluidStream_ThermofluidStream_Processes_Tests_Compressor.fmu - startTime: 0.000000 - stopTime: 30.000000 - tolerance: 0.000001 - stepSize: 0.030000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/Media/myMedia/Interfaces.mo:1022:7-1022:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sink.inlet.state.T >= 1.0 and sink.inlet.state.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= sink.inlet.state.T <= 1e4, has value: -694.44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/Media/myMedia/Interfaces.mo:1022:7-1022:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((junctionN.inlets[2].state.T >= 1.0 and junctionN.inlets[2].state.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= junctionN.inlets[2].state.T <= 1e4, has value: -704.286" info: maximum step size for 'model.root': 0.030000 info: Result file: ThermofluidStream_ThermofluidStream.Processes.Tests.Compressor_res.mat (bufferSize=1) info: Variable model.root.ThermofluidStream_ThermofluidStream_Processes_Tests_Compressor.sink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Processes_Tests_Compressor.sink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Processes_Tests_Compressor.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Processes_Tests_Compressor.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Processes_Tests_Compressor.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Processes_Tests_Compressor.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 1155 NumRhsEvals = 1271 NumLinSolvSetups = 128 NumNonlinSolvIters = 1270 NumNonlinSolvConvFails = 1 NumErrTestFails = 30 info: 2 warnings info: 0 errors