/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_ThermofluidStream.Boundaries.Tests.Reservoir_res.mat --tempDir=temp_ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir_fmu --startTime=0 --stopTime=10 --stepSize=0.01 --timeout=1200 --tolerance=1e-06 ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.Boundaries.Tests.Reservoir" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.Boundaries.Tests.Reservoir" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.Boundaries.Tests.Reservoir/model-h9s1vbbj" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir.fmu - startTime: 0.000000 - stopTime: 10.000000 - tolerance: 0.000001 - stepSize: 0.010000 info: maximum step size for 'model.root': 0.010000 info: Result file: ThermofluidStream_ThermofluidStream.Boundaries.Tests.Reservoir_res.mat (bufferSize=1) info: Variable model.root.ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir.conductionElement.conductionString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir.conductionElement.parameterString will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir.sink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir.sink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable model.root.ThermofluidStream_ThermofluidStream_Boundaries_Tests_Reservoir.source.displayPos4 will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/Boundaries/Internal/PartialVolume.mo:115:3-115:112:writable] | | | | The following assertion has been violated at time 0.140000 | | | | ((flowResistance2.inlet.m_flow > reservoir.m_flow_assert)) --> "Positive mass flow rate at Volume outlet" info: Final Statistics for 'model.root': NumSteps = 705 NumRhsEvals = 713 NumLinSolvSetups = 40 NumNonlinSolvIters = 712 NumNonlinSolvConvFails = 0 NumErrTestFails = 1 info: 2 warnings info: 0 errors