/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_Volume_TestSteamDryer_fmu --startTime=0 --stopTime=10 --stepSize=0.004 --timeout=50 --tolerance=1e-06 ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_Volume_TestSteamDryer.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestSteamDryer" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestSteamDryer" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestSteamDryer/model-eufolxv4" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_Volume_TestSteamDryer.fmu - startTime: 0.000000 - stopTime: 10.000000 - tolerance: 0.000001 - stepSize: 0.004000 info: model doesn't contain any continuous state info: maximum step size for 'model.root': 0.004000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 2501 NumRhsEvals = 2502 NumLinSolvSetups = 126 NumNonlinSolvIters = 2501 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors