/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestIdealSwitchValve_fmu --startTime=0 --stopTime=100 --stepSize=0.04 --timeout=50 --tolerance=1e-06 ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestIdealSwitchValve.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve/model-gskn7fq0" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestIdealSwitchValve.fmu - startTime: 0.000000 - stopTime: 100.000000 - tolerance: 0.000001 - stepSize: 0.040000 info: model doesn't contain any continuous state info: maximum step size for 'model.root': 0.040000 info: Result file: model_res.mat (bufferSize=10) error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve/model-gskn7fq0/temp/0001_ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestIdealSwitchValve/logStatusError: Model error: Argument of acos(p / 2.2064e7) outside the domain -1.0 <= -43164.5 <= 1.0 error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve/model-gskn7fq0/temp/0001_ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestIdealSwitchValve/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStepCVODE] fmi2_completedIntegratorStep failed for FMU "model.root.ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestIdealSwitchValve" warning: Bad return code at time 10.040000 error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve/model-gskn7fq0/temp/0001_ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestIdealSwitchValve/logStatusError: Model error: Argument of acos(p / 2.2064e7) outside the domain -1.0 <= -43164.5 <= 1.0 error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve/model-gskn7fq0/temp/0001_ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestIdealSwitchValve/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable perteDP2.C2.a error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 3 NumRhsEvals = 4 NumLinSolvSetups = 3 NumNonlinSolvIters = 3 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 3 warnings info: 7 errors