Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8765/0.8765, allocations: 152.6 MB / 168.9 MB, free: 15.03 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestCentrifugalPump4",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestCentrifugalPump4",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.0005101/0.0005101, allocations: 16.58 kB / 244.5 MB, free: 15.92 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.06047/0.06098, allocations: 33.07 MB / 277.5 MB, free: 1.121 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4): time 1.743/1.804, allocations: 302.6 MB / 0.5665 GB, free: 0.8867 MB / 446.1 MB Notification: Performance of NFInst.instExpressions: time 0.5707/2.375, allocations: 184.5 MB / 0.7467 GB, free: 14.93 MB / 0.5919 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0005816/2.375, allocations: 5.016 kB / 0.7467 GB, free: 14.93 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:118:3-120:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:121:3-123:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:127:3-131:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:71:3-72:53:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:73:3-74:53:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:78:3-79:55:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:80:3-81:51:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:49:3-50:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:51:3-53:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/ElectroMechanics/BoundaryConditions/SourceMechanicalPower.mo:5:3-9:24:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0006147/2.376, allocations: 205.8 kB / 0.7469 GB, free: 14.92 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:74:3-74:88:writable] Error: cardinality may only be used in the condition of an if-statement/equation or an assert. Notification: Performance of FrontEnd: time 8.179e-05/2.376, allocations: 41.97 kB / 0.7469 GB, free: 14.92 MB / 0.5919 GB " [Timeout remaining time 657] [Calling sys.exit(0), Time elapsed: 3.924966558930464] Failed to read output from testmodel.py, exit status != 0: 2.5400381750660017 2.5549475680000002 -1.0 Calling exit ...