/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_ThermoPower_ThermoPower_Test_WaterComponents_ValveZeroFlow_fmu --startTime=0 --stopTime=1 --stepSize=0.0004 --timeout=50 --tolerance=1e-06 ThermoPower_ThermoPower_Test_WaterComponents_ValveZeroFlow.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.ValveZeroFlow" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.ValveZeroFlow" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.ValveZeroFlow/model-acwywp9n" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermoPower_ThermoPower_Test_WaterComponents_ValveZeroFlow.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.000400 info: model doesn't contain any continuous state info: maximum step size for 'model.root': 0.000400 info: Result file: model_res.mat (bufferSize=10) error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.ValveZeroFlow/model-acwywp9n/temp/0001_ThermoPower_ThermoPower_Test_WaterComponents_ValveZeroFlow/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Media/Water/IF97_Utilities.mo:2897: IF97 medium function tsat called with too low pressure p = -1.31862e+11 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.ValveZeroFlow/model-acwywp9n/temp/0001_ThermoPower_ThermoPower_Test_WaterComponents_ValveZeroFlow/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStepCVODE] fmi2_completedIntegratorStep failed for FMU "model.root.ThermoPower_ThermoPower_Test_WaterComponents_ValveZeroFlow" warning: Bad return code at time 0.300400 error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.ValveZeroFlow/model-acwywp9n/temp/0001_ThermoPower_ThermoPower_Test_WaterComponents_ValveZeroFlow/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Media/Water/IF97_Utilities.mo:2897: IF97 medium function tsat called with too low pressure p = -1.31862e+11 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Test.WaterComponents.ValveZeroFlow/model-acwywp9n/temp/0001_ThermoPower_ThermoPower_Test_WaterComponents_ValveZeroFlow/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable system.allowFlowReversal error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 2 NumRhsEvals = 3 NumLinSolvSetups = 2 NumNonlinSolvIters = 2 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 3 warnings info: 7 errors