/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_ThermoPower_ThermoPower_Examples_HRB_Simulators_ClosedLoopDigitalSimulator_fmu --startTime=0 --stopTime=400 --stepSize=0.16 --timeout=50 --tolerance=1e-06 ThermoPower_ThermoPower_Examples_HRB_Simulators_ClosedLoopDigitalSimulator.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulator" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulator" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulator/model-l6ve3m49" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ThermoPower_ThermoPower_Examples_HRB_Simulators_ClosedLoopDigitalSimulator.fmu - startTime: 0.000000 - stopTime: 400.000000 - tolerance: 0.000001 - stepSize: 0.160000 error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulator/model-l6ve3m49/temp/0001_ThermoPower_ThermoPower_Examples_HRB_Simulators_ClosedLoopDigitalSimulator/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Media/Water/IF97_Utilities.mo:6433: Error in region computation of IF97 steam tables(p = 499002, h = -22076.3) error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ThermoPower_ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulator/model-l6ve3m49/temp/0001_ThermoPower_ThermoPower_Examples_HRB_Simulators_ClosedLoopDigitalSimulator/logFmi2Call: fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.ThermoPower_ThermoPower_Examples_HRB_Simulators_ClosedLoopDigitalSimulator" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 5 errors