/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_FluidDynamics_BaseClasses_test_FreeAeraulicConvection_fmu --startTime=0 --stopTime=1 --stepSize=0.002 --timeout=50 --tolerance=1e-06 TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_FluidDynamics_BaseClasses_test_FreeAeraulicConvection.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.FluidDynamics.BaseClasses.test_FreeAeraulicConvection" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.FluidDynamics.BaseClasses.test_FreeAeraulicConvection" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.FluidDynamics.BaseClasses.test_FreeAeraulicConvection/model-x4pkt41w" info: *** FMU Simulation Info *** - model: model (model exchange) - path: TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_FluidDynamics_BaseClasses_test_FreeAeraulicConvection.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.002000 info: maximum step size for 'model.root': 0.002000 info: Result file: model_res.mat (bufferSize=10) warning: [fmi2Warning] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.FluidDynamics.BaseClasses.test_FreeAeraulicConvection/model-x4pkt41w/temp/0001_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_FluidDynamics_BaseClasses_test_FreeAeraulicConvection/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:20: the Rayleigh number < 10^9 is out of the range of the correlation. => Correlation extrapolated info: Final Statistics for 'model.root': NumSteps = 505 NumRhsEvals = 510 NumLinSolvSetups = 30 NumNonlinSolvIters = 509 NumNonlinSolvConvFails = 0 NumErrTestFails = 1 info: 3 warnings info: 0 errors