/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_TAeZoSysPro_TAeZoSysPro_HeatTransfer_Functions_FreeConvection_Tests_horizontal_cylinder_ASHRAE_fmu --startTime=1 --stopTime=12 --stepSize=0.11 --timeout=50 --tolerance=1e-06 TAeZoSysPro_TAeZoSysPro_HeatTransfer_Functions_FreeConvection_Tests_horizontal_cylinder_ASHRAE.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TAeZoSysPro_TAeZoSysPro.HeatTransfer.Functions.FreeConvection.Tests.horizontal_cylinder_ASHRAE" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TAeZoSysPro_TAeZoSysPro.HeatTransfer.Functions.FreeConvection.Tests.horizontal_cylinder_ASHRAE" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TAeZoSysPro_TAeZoSysPro.HeatTransfer.Functions.FreeConvection.Tests.horizontal_cylinder_ASHRAE/model-c6mkog1u" info: *** FMU Simulation Info *** - model: model (model exchange) - path: TAeZoSysPro_TAeZoSysPro_HeatTransfer_Functions_FreeConvection_Tests_horizontal_cylinder_ASHRAE.fmu - startTime: 1.000000 - stopTime: 12.000000 - tolerance: 0.000001 - stepSize: 0.110000 info: model doesn't contain any continuous state warning: [fmi2Warning] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/TAeZoSysPro_TAeZoSysPro.HeatTransfer.Functions.FreeConvection.Tests.horizontal_cylinder_ASHRAE/model-c6mkog1u/temp/0001_TAeZoSysPro_TAeZoSysPro_HeatTransfer_Functions_FreeConvection_Tests_horizontal_cylinder_ASHRAE/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/horizontal_cylinder_ASHRAE.mo:15: the Rayleigh number <10^9 is out of the range of the correlation info: maximum step size for 'model.root': 0.110000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 102 NumRhsEvals = 103 NumLinSolvSetups = 7 NumNonlinSolvIters = 102 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 3 warnings info: 0 errors