/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ScalableTestSuite_ScalableTestSuite.Mechanical.FlexibleBeam.ScaledExperiments.FlexibleBeamModelica_N_8_res.mat --tempDir=temp_ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8_fmu --startTime=0 --stopTime=0.04 --stepSize=2.001e-05 --timeout=300 --tolerance=3e-08 ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ScalableTestSuite_ScalableTestSuite.Mechanical.FlexibleBeam.ScaledExperiments.FlexibleBeamModelica_N_8" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ScalableTestSuite_ScalableTestSuite.Mechanical.FlexibleBeam.ScaledExperiments.FlexibleBeamModelica_N_8" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ScalableTestSuite_ScalableTestSuite.Mechanical.FlexibleBeam.ScaledExperiments.FlexibleBeamModelica_N_8/model-90oq6zp2" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.fmu - startTime: 0.000000 - stopTime: 0.040000 - tolerance: 0.000000 - stepSize: 0.000020 LOG_STDOUT | info | Using sparse solver for linear system 0, | | | | because density of 0.015 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | Using sparse solver for linear system 1, | | | | because density of 0.016 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. info: maximum step size for 'model.root': 0.000020 info: Result file: ScalableTestSuite_ScalableTestSuite.Mechanical.FlexibleBeam.ScaledExperiments.FlexibleBeamModelica_N_8_res.mat (bufferSize=1) info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.bodybox[1].frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.bodybox[2].frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.bodybox[3].frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.bodybox[4].frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.bodybox[5].frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.bodybox[6].frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.bodybox[7].frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.bodybox1.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.bodyboxN.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.world.label1 will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ScalableTestSuite_ScalableTestSuite_Mechanical_FlexibleBeam_ScaledExperiments_FlexibleBeamModelica_N_8.world.label2 will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 14935 NumRhsEvals = 16130 NumLinSolvSetups = 876 NumNonlinSolvIters = 16129 NumNonlinSolvConvFails = 0 NumErrTestFails = 47 info: 2 warnings info: 0 errors