/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_PowerSysPro_PowerSysPro_Examples_UsingDiesel_OneDieselRescuingOneLoad_fmu --startTime=0 --stopTime=60 --stepSize=0.024 --timeout=50 --tolerance=1e-06 PowerSysPro_PowerSysPro_Examples_UsingDiesel_OneDieselRescuingOneLoad.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.UsingDiesel.OneDieselRescuingOneLoad" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.UsingDiesel.OneDieselRescuingOneLoad" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.UsingDiesel.OneDieselRescuingOneLoad/model-xxgzz0wp" info: *** FMU Simulation Info *** - model: model (model exchange) - path: PowerSysPro_PowerSysPro_Examples_UsingDiesel_OneDieselRescuingOneLoad.fmu - startTime: 0.000000 - stopTime: 60.000000 - tolerance: 0.000001 - stepSize: 0.024000 info: model doesn't contain any continuous state info: maximum step size for 'model.root': 0.024000 info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated at time 30.024000 | | | | ((not load.U < load.minU)) --> ">>> Voltage is below the minimum acceptable value for OneDieselRescuingOneLoad.load" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:194:9-194:152:writable] | | | | The following assertion has been violated at time 30.024000 | | | | ((line.IA <= 50.0)) --> ">>> Current flowing the line is exceeding the maximum admissible current for OneDieselRescuingOneLoad.line" info: Final Statistics for 'model.root': NumSteps = 1252 NumRhsEvals = 1253 NumLinSolvSetups = 65 NumNonlinSolvIters = 1252 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors