/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_PowerSysPro_PowerSysPro_Examples_StructuredNetwork_DoubleNetworkWithVariableLoads_fmu --startTime=0 --stopTime=1 --stepSize=0.0004 --timeout=50 --tolerance=1e-06 PowerSysPro_PowerSysPro_Examples_StructuredNetwork_DoubleNetworkWithVariableLoads.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.StructuredNetwork.DoubleNetworkWithVariableLoads" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.StructuredNetwork.DoubleNetworkWithVariableLoads" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/PowerSysPro_PowerSysPro.Examples.StructuredNetwork.DoubleNetworkWithVariableLoads/model-6dgujwzs" info: *** FMU Simulation Info *** - model: model (model exchange) - path: PowerSysPro_PowerSysPro_Examples_StructuredNetwork_DoubleNetworkWithVariableLoads.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.000400 info: model doesn't contain any continuous state LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not feeder1.load4.U < feeder1.load4.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetworkWithVariableLoads.feeder1.load4" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not feeder1.load1.U < feeder1.load1.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetworkWithVariableLoads.feeder1.load1" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not feeder2.load4.U < feeder2.load4.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetworkWithVariableLoads.feeder2.load4" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not feeder2.load1.U < feeder2.load1.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetworkWithVariableLoads.feeder2.load1" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:484:11-484:161:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((src.tra2.SA <= 2.5e5)) --> ">>> Apparent power flowing the transformer is exceeding the nominal power for DoubleNetworkWithVariableLoads.src.tra2" info: maximum step size for 'model.root': 0.000400 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 2501 NumRhsEvals = 2502 NumLinSolvSetups = 126 NumNonlinSolvIters = 2501 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors