/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_OpenHydraulics_OpenHydraulics_DevelopmentTests_CheckValveTest2_fmu --startTime=0 --stopTime=5 --stepSize=0.002 --timeout=50 --tolerance=1e-06 OpenHydraulics_OpenHydraulics_DevelopmentTests_CheckValveTest2.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/OpenHydraulics_OpenHydraulics.DevelopmentTests.CheckValveTest2" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/OpenHydraulics_OpenHydraulics.DevelopmentTests.CheckValveTest2" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/OpenHydraulics_OpenHydraulics.DevelopmentTests.CheckValveTest2/model-et339in2" info: *** FMU Simulation Info *** - model: model (model exchange) - path: OpenHydraulics_OpenHydraulics_DevelopmentTests_CheckValveTest2.fmu - startTime: 0.000000 - stopTime: 5.000000 - tolerance: 0.000001 - stepSize: 0.002000 info: maximum step size for 'model.root': 0.002000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_CheckValveTest2.checkValve.variableRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_CheckValveTest2.checkValve.variableRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_CheckValveTest2.checkValve1.variableRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_CheckValveTest2.checkValve1.variableRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_CheckValveTest2.oil.oilName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 3239 NumRhsEvals = 4984 NumLinSolvSetups = 407 NumNonlinSolvIters = 4983 NumNonlinSolvConvFails = 5 NumErrTestFails = 102 info: 2 warnings info: 0 errors