/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Modelica_3.2.3_Modelica.Magnetic.FluxTubes.Examples.SolenoidActuator.ComparisonPullInStroke_res.mat --tempDir=temp_Modelica_3_2_3_Modelica_Magnetic_FluxTubes_Examples_SolenoidActuator_ComparisonPullInStroke_fmu --startTime=0 --stopTime=0.05 --stepSize=9.01713e-06 --timeout=50 --tolerance=1e-07 Modelica_3_2_3_Modelica_Magnetic_FluxTubes_Examples_SolenoidActuator_ComparisonPullInStroke.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Magnetic.FluxTubes.Examples.SolenoidActuator.ComparisonPullInStroke" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Magnetic.FluxTubes.Examples.SolenoidActuator.ComparisonPullInStroke" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Magnetic.FluxTubes.Examples.SolenoidActuator.ComparisonPullInStroke/model-lt75tcej" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Modelica_3_2_3_Modelica_Magnetic_FluxTubes_Examples_SolenoidActuator_ComparisonPullInStroke.fmu - startTime: 0.000000 - stopTime: 0.050000 - tolerance: 0.000000 - stepSize: 0.000009 info: maximum step size for 'model.root': 0.000009 info: Result file: Modelica_3.2.3_Modelica.Magnetic.FluxTubes.Examples.SolenoidActuator.ComparisonPullInStroke_res.mat (bufferSize=1) info: Parameter model.root.Modelica_3_2_3_Modelica_Magnetic_FluxTubes_Examples_SolenoidActuator_ComparisonPullInStroke.comparisonWithFEA.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Modelica_3_2_3_Modelica_Magnetic_FluxTubes_Examples_SolenoidActuator_ComparisonPullInStroke.comparisonWithFEA.tableName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 12 NumRhsEvals = 13 NumLinSolvSetups = 3 NumNonlinSolvIters = 12 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors