/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Modelica_3.2.3_Modelica.Fluid.Examples.AST_BatchPlant.Test.TanksWithEmptyingPipe1_res.mat --tempDir=temp_Modelica_3_2_3_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1_fmu --startTime=0 --stopTime=120 --stepSize=0.0239091 --timeout=50 --tolerance=1e-06 Modelica_3_2_3_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Fluid.Examples.AST_BatchPlant.Test.TanksWithEmptyingPipe1" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Fluid.Examples.AST_BatchPlant.Test.TanksWithEmptyingPipe1" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Modelica_3.2.3_Modelica.Fluid.Examples.AST_BatchPlant.Test.TanksWithEmptyingPipe1/model-uq2op0l7" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Modelica_3_2_3_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1.fmu - startTime: 0.000000 - stopTime: 120.000000 - tolerance: 0.000001 - stepSize: 0.023909 info: maximum step size for 'model.root': 0.023909 info: Result file: Modelica_3.2.3_Modelica.Fluid.Examples.AST_BatchPlant.Test.TanksWithEmptyingPipe1_res.mat (bufferSize=1) info: Final Statistics for 'model.root': NumSteps = 101 NumRhsEvals = 102 NumLinSolvSetups = 7 NumNonlinSolvIters = 101 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors