/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ModelicaTest_trunk_ModelicaTest.Fluid.TestExamplesVariants.HeatingSystem_FixedInitial_res.mat --tempDir=temp_ModelicaTest_trunk_ModelicaTest_Fluid_TestExamplesVariants_HeatingSystem_FixedInitial_fmu --startTime=0 --stopTime=6000 --stepSize=1.19904 --timeout=50 --tolerance=1e-06 ModelicaTest_trunk_ModelicaTest_Fluid_TestExamplesVariants_HeatingSystem_FixedInitial.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ModelicaTest_trunk_ModelicaTest.Fluid.TestExamplesVariants.HeatingSystem_FixedInitial" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ModelicaTest_trunk_ModelicaTest.Fluid.TestExamplesVariants.HeatingSystem_FixedInitial" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ModelicaTest_trunk_ModelicaTest.Fluid.TestExamplesVariants.HeatingSystem_FixedInitial/model-w8tvycmo" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ModelicaTest_trunk_ModelicaTest_Fluid_TestExamplesVariants_HeatingSystem_FixedInitial.fmu - startTime: 0.000000 - stopTime: 6000.000000 - tolerance: 0.000001 - stepSize: 1.199040 error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ModelicaTest_trunk_ModelicaTest.Fluid.TestExamplesVariants.HeatingSystem_FixedInitial/model-w8tvycmo/temp/0001_ModelicaTest_trunk_ModelicaTest_Fluid_TestExamplesVariants_HeatingSystem_FixedInitial/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Fluid/Utilities.mo:614: regFun3(): Derivatives at data points do not allow co-monotone interpolation, as both are non-zero, of opposite sign and have an absolute value larger than machine eps (y0d = 0.000271073, y1d = -0.01086). Please correct arguments. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ModelicaTest_trunk_ModelicaTest.Fluid.TestExamplesVariants.HeatingSystem_FixedInitial/model-w8tvycmo/temp/0001_ModelicaTest_trunk_ModelicaTest_Fluid_TestExamplesVariants_HeatingSystem_FixedInitial/logFmi2Call: fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.ModelicaTest_trunk_ModelicaTest_Fluid_TestExamplesVariants_HeatingSystem_FixedInitial" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 5 errors