Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr LibRAS_LibRAS.Tanks.FishTank.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001767/0.001767, allocations: 108.7 kB / 17.17 MB, free: 5.867 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001896/0.001896, allocations: 197.4 kB / 20.12 MB, free: 2.93 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.422/1.422, allocations: 207.6 MB / 230.5 MB, free: 4.074 MB / 174.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/package.mo): time 0.04262/0.04262, allocations: 5.574 MB / 287.9 MB, free: 10.77 MB / 238.1 MB " [Timeout remaining time 180] Using package LibRAS with version (/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(LibRAS.Tanks.FishTank,fileNamePrefix="LibRAS_LibRAS_Tanks_FishTank",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(LibRAS.Tanks.FishTank,fileNamePrefix="LibRAS_LibRAS_Tanks_FishTank",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: LibRAS requested package Modelica of version 3.2.2. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002169/0.002169, allocations: 70.23 kB / 402.5 MB, free: 4.219 MB / 286.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2884/0.2906, allocations: 50.43 MB / 452.9 MB, free: 5.367 MB / 318.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/LibRAS master/Tanks/FishTank.mo:26:33-26:43:writable] Error: Modified element unit not found in class Integer. Notification: Performance of FrontEnd: time 0.002527/0.2931, allocations: 1.405 MB / 454.3 MB, free: 4.383 MB / 318.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.5025484529323876] Failed to read output from testmodel.py, exit status != 0: 0.29882555920630693 0.31215376 -1.0 Calling exit ...