/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IDEAS_dev_IDEAS_Fluid_HeatExchangers_Examples_DryCoilEffectivenessNTUMassFlow_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=50 --tolerance=1e-06 IDEAS_dev_IDEAS_Fluid_HeatExchangers_Examples_DryCoilEffectivenessNTUMassFlow.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.HeatExchangers.Examples.DryCoilEffectivenessNTUMassFlow" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.HeatExchangers.Examples.DryCoilEffectivenessNTUMassFlow" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.HeatExchangers.Examples.DryCoilEffectivenessNTUMassFlow/model-z6fylow6" info: *** FMU Simulation Info *** - model: model (model exchange) - path: IDEAS_dev_IDEAS_Fluid_HeatExchangers_Examples_DryCoilEffectivenessNTUMassFlow.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 info: maximum step size for 'model.root': 1.440000 info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/HeatExchangers/BaseClasses/PartialEffectivenessNTU.mo:180:5-189:38:writable] | | | | The following assertion has been violated at time 1998.720000 | | | | ((noEvent(hex.m1_flow > (-0.1) * hex.m1_flow_nominal) and noEvent(hex.m2_flow > (-0.1) * hex.m2_flow_nominal))) --> "*** Warning in DryCoilEffectivenessNTUMassFlow.hex: The flow direction reversed. | | | | However, because the constant use_dynamicFlowRegime is set to false, | | | | the model does not change equations based on the actual flow regime. | | | | To switch equations based on the actual flow regime during the simulation, | | | | set the constant use_dynamicFlowRegime=true. | | | | Note that this can lead to slow simulation because of events." info: Final Statistics for 'model.root': NumSteps = 754 NumRhsEvals = 755 NumLinSolvSetups = 42 NumNonlinSolvIters = 754 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors