/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IDEAS_IDEAS_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT_fmu --startTime=0 --stopTime=603900 --stepSize=900 --timeout=50 --tolerance=1e-06 IDEAS_IDEAS_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.FixedResistances.Validation.PlugFlowPipes.PlugFlowAIT/model-cdck7z78" info: *** FMU Simulation Info *** - model: model (model exchange) - path: IDEAS_IDEAS_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.fmu - startTime: 0.000000 - stopTime: 603900.000000 - tolerance: 0.000001 - stepSize: 900.000000 LOG_STDOUT | info | ... loading "dat" from "/tmp/fmi4c_XCpOhl/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Resources/Data/Fluid/FixedResistances/Validation/PlugFlowPipes/PipeDataAIT151218.mos" info: maximum step size for 'model.root': 900.000000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.IDEAS_IDEAS_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.DataReader.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.DataReader.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.IDEAS_IDEAS_Fluid_FixedResistances_Validation_PlugFlowPipes_PlugFlowAIT.pipeDataAIT151218.filNam will not be stored in the result file, because the signal type is not supported [CVODE ERROR] CVode At t = 276.05, mxstep steps taken before reaching tout. error: [doStepCVODE] CVode failed with flag = -1 warning: Bad return code at time 276.050128 error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 1000 NumRhsEvals = 2027 NumLinSolvSetups = 370 NumNonlinSolvIters = 2026 NumNonlinSolvConvFails = 56 NumErrTestFails = 55 info: 3 warnings info: 2 errors